Scanner Parameters
Counts (Read-only)
Power-On
16-bit counter that increments on scanner power-on.
Used for detecting unwanted resets caused by power supply problems or ESD transients.
Returns the number of times the scanner has been re-powered or a watchdog reset
occurs.
0 to 65,535 power-ons.
Resets
16-bit counter that increments every time the scanner is reset. Value is reset on power-on.
Used for detecting unwanted resets caused by power supply problems or ESD transients.
Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware defaults. A watchdog
reset is a reset that is forced whenever the software locks up.
0 to 65,535 resets.
Power-On Saves
16-bit counter that increments every time a scanner setting is saved for power-on.
Custom Default Saves
16-bit counter that increments every time a scanner setting is saved to the customer
parameter section of flash memory.
5-177