Chapter 4 TL1 Reference
Commands

Retrieve Alarm Equipment

This command displays current alarms for the specified equipment. The command
format is:
RTRV-ALM-EQPT:[<tid>]:<aid>:<ctag>;
Aid
TS3100
SPAN-x
RO-x
GPS
If there are no alarms:
<sid> <date> <time>
M <ctag> COMPLD
/*LINK:<link>,CMD:<command>*/
;
If there is at least one alarm:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<condtype>,<srveff>,
/
;
Refer to
Chapter 5,
recommended action.
130 TimeSource User's Guide
Value
System (all TS3100 alarms)
x = A
E1 span A input
x = B
E1 span B input
x = A
Remote oscillator A input
x = B
Remote oscillator B input
GPS receiver
<ocrdat>,<ocrtm>,,:\"<conddescr>\""..
*LINK:<link>,CMD:<command>*/
Troubleshooting, for a list of all <conddescr> messages, and the
Item Addressed
097-72020-01 Revision K – December 2005