Symmetricom TimeSource 3100 User Manual page 114

Gps primary reference source
Hide thumbs Also See for TimeSource 3100:
Table of Contents

Advertisement

Chapter 4 TL1 Reference
Commands
Aid
Parameter
TS3100
ROFREQ=a
TOD=a
ALMCOND=a
IPNE=a.b.c.d
(See Note 1)
IPSUBNET=a.b.c.d
(See Note 1)
IPGATE=a.b.c.d
(See Note 1)
114 TimeSource User's Guide
Value
a=5 or 10
Frequency for both remote oscillator inputs
in MHz
a=CISCO
Serial TOD message sent in CISCO format
a=NTP4
Serial TOD message sent in NTP4 format
a=NONE
No serial message sent
a=ALW
Alarm conditioning for E1, TOD, and IRIG-B
outputs is enabled
a=INH
Alarm conditioning for E1, TOD, and IRIG-B,
outputs is disabled
a = 0 to 255
IP address of this TimeSource 3100
(command must be sent from COM1,
b = 0 to 255
COM2, or Craft port to set this parameter)
c = 0 to 255
d = 0 to 255
a = 0 to 255
Subnet mask for this TimeSource 3100
(command must be sent from COM1,
b = 0 to 255
COM2, or Craft port to set this parameter)
c = 0 to 255
d = 0 to 255
a = 0 to 255
Default gateway IP address for this
TimeSource 3100 (command must be sent
b = 0 to 255
from COM1, COM2, or Craft port to set this
parameter)
c = 0 to 255
d = 0 to 255
Description
097-72020-01 Revision K – December 2005

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TimeSource 3100 and is the answer not in the manual?

Table of Contents