T1 Parameters Web Screen - General DataComm spectracomm ip Installation & Operation Manual

Router card
Table of Contents

Advertisement

The Web Interface

T1 Parameters Web Screen

The T1 Configuration screen displays all of the T1 configuration parameters. To change a particular
configuration parameter, click on the adjacent down arrow to open a drop-down list of selectable
configuration options for that parameter. Continue to change other parameters in the same manner.
When all desired changes have been made, click on the Save button.
Table 4-7
T1 Configuration Screen
Clock Source
Framing
Line Coding
Line Buildout/Pre-equalization
FDL
Remote Loopback
Timeslot Format
Starting DS0
Number of DS0's
Save Button
Reset Button
076R200-000
Issue 2
Field
Description
Select: Line or Internal
Select: ESF, D4 or Auto
Select: B8ZS or AMI
Select:
DS1 Auto Line Buildout
DS1 0.0dB Line Buildout
DS1 -7.5dB Line Buildout
DS1 -15.0dB Line Buildout
DS1 -22.5dB Line Buildout
Select: ANSI-T1.403 or TR-54016
Select: Inhibit, Payload Loop, or Line Loop
Select N x 56 or N x 64 Kbps
Select Timeslot: 1 - 24
Select Timeslot: 1 - 24
Click to save the T1 configuration parameters to the unit.
Click to discard unsaved edits and reset options to previous settings.
SpectraComm IP Router Card
Installation and Operation Manual
SC-IP Web Screens
DSX1 0 - 133 ft Pre-equalization
DSX1 133 - 266 ft Pre-equalization
DSX1 266 - 399 ft Pre-equalization
DSX1 399 - 533 ft Pre-equalization
DSX1 533 - 655 ft Pre-equalization