In this procedure, the SC-IP's default value for each PPP network parameter is shown in the
command string as: [default]. If the default value applies to your network, you do not need to re-
enter it. Otherwise, use the CLI to set the configuration value as required. Type ? following any
command, sub-command or parameter for context-sensitive online help.
Note
Some ADMIN mode configuration commands (i.e., enabling the craft port or setting up user accounts)
cannot be accessed or executed via the web interface.
1. After initializing the SC-IP for configuration, perform the following steps to configure the unit
as an IP router in a PPP (leased line) network
2. Set the system prompt by typing:
configure prompt
3. Configure the T1 values for your network.
configure t1 clock-source
configure t1 fdl
configure t1 framing
configure t1 lbo ds1
configure t1 linecode
configure t1 loopback
configure t1 timeslots
Note
When configuring the Line Buildout for DSX1, SC-IP uses five ranges of lengths: 0 - 133 ft, 133-266 ft,
266-399 ft, 399 - 533 ft, 533-655 ft. Be aware that if you select a value at the beginning of a range, such as
133 ft, SC-IP will use the lower range that includes that value.
Note
Type
show T1
4. Configure the Ethernet IP address and mask by typing:
configure interfaces ip-address ethernet0
5. Enter a description of the Ethernet interface by typing:
configure interfaces description ethernet0
6. Enable the Ethernet interface by typing:
configure interfaces enable ethernet0
7.
Configure the serial0 interface for PPP by typing:
configure interface link-encap serial0 ppp
8. When the Warning message appears, type Y.
076R200-000
Issue 2
[your_site]
[line]
[ANSI-T1.403]
[ESF]
[0.0dB]
[B8ZS]
[INHIBIT]
[1-24 64]
to check your T1 value entries. Modify, if needed.