5 Connecting to an External System

The following sections describe how to connect the reader to another system. Note that the reader requires
more power than a typical proximity reader and should have its own power supply.

Wiegand/Magstripe

The reader can be connected to a typical access control system using Wiegand/Magstripe. The access
control system can control the reader's LED indicator using inputs IN1 and IN2. Input IN3 can be connected
to a presence detector such as an inductive loop. An overview is shown in Figure 21.
CL/LOAD
D0/CLK
D1/DATA
GND
IN1+
IN1-
IN2+
IN2-
IN3+
IN3-
Figure 21 Reader connected to access control system using Wiegand/Magstripe
For common access control systems, the reader can be configured using DIP switches as described in
section 5.1.1, "Easy Configuration", below. For other systems, all Wiegand/Magstripe settings are available
under Settings.../Interfaces.../Wieg/Mag in the web interface.

5.1.1 Easy Configuration

The reader can be configured to work with common access control systems using DIP switches S101:6-8.
When any of these switches are in the ON position, the reader is configured to report tags once, accept
SecureMarkID tags only, and use the specified Wiegand/Magstripe format.
The following sections describe how to connect the reader to different access control systems and how to
set the reader's DIP switches. The following format is used to describe cable connections:
[READER SIGNAL]
ASSA ARX/RX WEB (with 500RW22)
5.1.1.1
Configure the ARX/RX WEB system to use card type Wiegand.
GND
0V
CL/LOAD
N/C
D0/CLK
D0
D1/DATA
D1
S101 - Wiegand format: W34N
S101
ON
1
8
Tested version: RX WEB PR300233 build-8418 version-17.2.0.5
Wiegand/Magstripe
Green LED
Red LED
Presence loop
[ACCESS CONTROL SYSTEM SIGNAL]
Access Control
System
Loop Controller
IN1+
12V
IN1-
LED_GREEN
IN2+
12V
IN2-
LED_RED
S301 - Vigilant pull-ups disabled
S301
ON
1
8