Wiegand Timing - TagMaster XT-1 Manual

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1/XT Mini Manual
W37N/H10302
S101
1
8
W37R/H10302
S101
1
8
M8N/H10320
S101
1
8
Table 5 Wiegand/Magstripe formats
Using DIP switches S301:6-8 it is possible to activate 1 kΩ pull-up resistors on D0/CLK, D1/DATA and
CL/LOAD. Details are shown in Figure 11.
5V
1kΩ
1kΩ
S301:6
S301:7
D0/CLK
Figure 11 Wiegand/Magstripe DIP switch configuration

3.3.1 Wiegand Timing

The following values apply when all outputs are pulled up to 5 V with 1 kΩ resistors.
Symbol
t
CL to D# setup time
SU
t
Fall time (all signals)
F
t
Rise time (all signals)
R
t
Pulse interval
PI
t
Pulse width
PW
t
CL hold time after last D# change
H
Table 6 Wiegand interface timing
37-bit Wiegand (35-bit data, no site code):
EDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDO
ON
XXXXXXXXXXXXXXXXXXX------------------
------------------XXXXXXXXXXXXXXXXXXX
37-bit Wiegand (37-bit data, no site code, no parity):
DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD
ON
8-digit Magstripe:
[25 zeroes]BDDDDDDDDFL[165 zeroes]
ON
1kΩ
S301:8
D1/DATA
CL/LOAD
GND
Parameter
13-111 05, 2015-08-14
Min
Typ
Max
1520
125
5
2
80
1840
Page 13 of 32
Unit
µs
ns
µs
ms
µs
µs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xt mini

Table of Contents