Magstripe Timing; Ethernet - TagMaster XT-1 Manual

Hide thumbs Also See for XT-1:
Table of Contents

Advertisement

XT-1/XT Mini Manual
CL
t
SU
D0
D1
Figure 12 Wiegand timing diagram

3.3.2 Magstripe Timing

The following values apply when all outputs are pulled up to 5 V with 1 kΩ resistors.
Symbol
t
LOAD to CLK setup time
SU
t
Fall time (all signals)
F
t
Rise time (all signals)
R
t
Clock low
CL
t
Clock high
CH
t
LOAD hold time after last CLK change
H
t
Data hold time
DH
Table 7 Magstripe interface timing
LOAD
t
SU
CLK
DATA
Figure 13 Magstripe timing diagram (note: data low = logic one)

Ethernet

The reader has a 10 Mbps/100 Mbps Ethernet interface with one (XT Mini) or two (XT-1) ports. The interface
supports auto crossover (Auto-MDIX) so that installation can be done using either patch cables or crossover
cables. Each port has two LED indicators for Link/Activity (Yellow/Flashing Yellow) and 10 Mbps/100 Mbps
speed (Off/Green).
Connections
Max cable length
Wire size
Table 8 Ethernet connection overview
The reader's default IP address and subnet mask can be found on a label on the backside of the reader.
The default address is on the format 10.x.x.x and the subnet mask is 255.0.0.0. All IP settings can be
t
PI
t
R
t
F
Parameter
t
CL
t
CH
t
DH
ETHERNET:A
ETHERNET:B (XT -1 only)
100 m
CAT5e cable or better is required for the Ethernet connection
t
t
PW
H
t
t
R
t
H
F
13-111 05, 2015-08-14
Min
Typ
1520
125
5
480
960
1520
880
Ethernet port
Ethernet port
Max
Unit
µs
ns
µs
µs
µs
µs
µs
Page 14 of 32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xt mini

Table of Contents