Test Parameters - Parameter Reference
2−180
Table 2−3: PID Parameters (Cont.)
Parameter
Identity
Description
PP53
COFDM Maximum PCR frequency drift rate
PP6
Minimum PID bit rate
PP60
IP Max PCR accuracy error
PP61
IP Max PCR overall jitter
PP62
IP Maximum PCR frequency offset
PP63
IP Maximum PCR frequency drift rate
PP7
Minimum PID bit rate
PP8
PID bit rate variability integration count
PP9
PID bit rate variability fraction
MTM400 MPEG Transport Stream Monitor Technical Reference
Nominal
Maximum
350
15000
Nominal
Maximum
0
300000000
Nominal
Maximum
500
50000
Nominal
Maximum
40000000
200000000
Nominal
Maximum
810
30000
Nominal
Maximum
75
15000
Nominal
Maximum
−1
300000000
Nominal
Maximum
10
30
Nominal
Maximum
0
1
Minimum
Units
10
mHz/s
Minimum
Units
0
bps
Minimum
Units
100
ns
Minimum
Units
0
ns
Minimum
Units
50
Hz
Minimum
Units
10
mHz/s
Minimum
Units
0
bps
Minimum
Units
2
integer > 0
Minimum
Units
0
fraction