1740a series; 1750a series waveform / vector monitor (143 pages)
Summary of Contents for Tektronix MTM400A
Page 1
Technical Reference MTM400A MPEG Transport Stream Monitor Specifications and Performance Verification 071-2496-00 This document applies to firmware versions 3.0 and above. www.tektronix.com...
Page 6
Table of Contents MTM400A Specifications and Performance Verification...
Page 7
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. MTM400A Specifications and Performance Verification...
Page 8
H WARNING indicates an injury hazard not immediately accessible as you read the marking. H CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: Protective Ground CAUTION Refer to Manual (Earth) Terminal MTM400A Specifications and Performance Verification...
Transport Stream Monitor: H Specifications lists the electrical, physical, and environmental specifications of the MTM400A monitor. H Performance Verification contains a procedure to verify that the MTM400A monitor is operating normally. Product Documentation Table i lists the product documentation supporting the MTM400A monitor.
Page 10
Provides instructions for upgrading the (075-0972-xx) product firmware Hardware Upgrade Instructions Provides instructions for installing the (075-0973-xx) optional hardware interface cards Key: Printed document MTM400A product documentation CD - PDF format Tektronix Web site - PDF format viii MTM400A Specifications and Performance Verification...
Specifications This section lists the electrical, environmental, and physical specifications of the MTM400A monitor. All specifications are guaranteed unless labeled typical. Typical specifications are provided for your convenience and are not guaranteed. Electrical characteristics apply to test systems operating within the environmen- tal conditions.
Output Bit Rate Same as the SMPTE310M input 600 mV min, 1.0 V max, into a 75 Ω load Signal Amplitude 75 Ω, transformer coupled Output Impedance Return Loss 10 dB min at 20 MHz 1- 2 MTM400A Specifications and Performance Verification...
Linear time code, SMPTE standard to ANSI/SMPTE 12M - 1995 Input Voltage 2.0 V p-p differentially minimum Table 1- 8: TS processor card - Ethernet RJ-45 connector Characteristic Description Connector 10/100 Base-T; RJ-45 Use only good quality screened cable; Cat 6 1- 4 MTM400A Specifications and Performance Verification...
Receiver Bandwidth, QAM B 6 MHz nominal Connector Type F type 75 Ω nominal Input Termination Impedance Input Return Loss 5 dB typical Ultimate Modulation Error Ratio with Equalizer 37 dB with equalizer; typical 1- 5 MTM400A Specifications and Performance Verification...
38 dB typical, with a 64 QAM input Receiver Bandwidth, QAM C 6 MHz nominal 75 Ω nominal Input Termination Impedance Input Return Loss 6 dB min, 10 dB typical, 88 MHz to 858 MHz 1- 6 MTM400A Specifications and Performance Verification...
- - 60 dBm to ensure compliance to EN 55103-2 immunity Modulation Format 8VSB in accordance with ATSC A/53B. Receiver Bandwidth 6 MHz 75 Ω nominal Input Termination Impedance Connector Type F type Input Return Loss 5 dB minimum; typical 1- 8 MTM400A Specifications and Performance Verification...
Equalizer filter tap information is displayed. Display Echo Level range: Normalized real tap values over the range of - - 1 to 1 Display Delay range: - - 6.7 μs to 45.5 μs 1- 9 MTM400A Specifications and Performance Verification...
1/2, 2/3, 3/4, 5/6, 7/8 Guard Intervals 1/32, 1/16, 1/8, 1/4 Spectrum Polarity The receiver will operate with both inverted and normal spectral polarity. Ultimate Modulation Error Ratio, with Equalizer 37 dB with equalizer; typical 1- 10 MTM400A Specifications and Performance Verification...
Table 1- 21: GigE interface card - Ethernet electrical port Characteristic Description Standard 10/100/1000BASE-T IEEE 802.3 Connector Type RJ-45 Data Format 10/100 Base T Data Format 1000 Base T Trellis encoded, PAM5 symbols full-duplex on 4-pair Cat-5 UTP per IEEE 802.3ab 1- 12 MTM400A Specifications and Performance Verification...
Termination Data Format Bi-phase coded. Compliant with SMPTE310M Input Bit Rate 19,392,658.5 bps 2.8 ppm Signal Amplitude 2.0V max; 200 mV pk to pk min Return Loss 10 dB min at 20 MHz 1- 14 MTM400A Specifications and Performance Verification...
2 (In single carrier) Voltage Capacity 210 mAh Continuous Discharge (Maximum) 3 mA Overall Dimensions (Single cell) Height 3.2 mm (0.13 in) Width (Diameter) 20 mm (0.79 in) Battery Type Tektronix part number: 146-0096-xx 1- 15 MTM400A Specifications and Performance Verification...
Top and bottom: 0 mm; Sides: Standard 19 in rack mount Weight 6.0 kg (13.3 lbs); fully loaded Packaged Dimensions Height 241 mm (9.5 in) Width 590 mm (23.1 in) Depth 760 mm (30 in) Weight (Packaged) 9 kg (19.7 lbs) 1- 16 MTM400A Specifications and Performance Verification...
U.S. Nationally Recognized Testing Laboratory UL61010B-1:2003 Standard for electrical measuring and test equipment. Listing Canadian Certification CAN/CSA C22.2 No. 1010.1:1997 Particular requirements for electrical equipment for measurement, control, and laboratory use. Part 1. 1- 17 MTM400A Specifications and Performance Verification...
Page 30
Pollution Degree 4 Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical outdoor locations. Pollution Degree Pollution Degree 2 (as defined in IEC61010-1). Rated for indoor use only. 1- 18 MTM400A Specifications and Performance Verification...
Mains fuse is 3.15 A, 250 V, Fast; Not operator replaceable. Refer servicing to qualified service personnel. Current Rating 1 Amp Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1) Note: Rated for indoor use only. 1- 19 MTM400A Specifications and Performance Verification...
Page 32
Specifications 1- 20 MTM400A Specifications and Performance Verification...
Page 35
Requirements The MTM400A monitor must be connected to a network and have a valid IP address as described in the MTM400A Quick Start User Manual. The client PC must satisfy the requirements listed in Table 1- -1 on page 1- -1.
Page 36
8. Click Connect to start the connection process. 9. Read the End User License Agreement if it appears, and then click I Accept. 10. When the MTM400A monitor RUI opens, click Device in the button bar to display the Device Information view (see Figure 2- -1).
Need help?
Do you have a question about the MTM400A and is the answer not in the manual?
Questions and answers