PID Parameters
MTM400 MPEG Transport Stream Monitor Technical Reference
Table 2−3 shows the parameters associated with PIDs.
<PIDS></PIDS>
Description
Container for all individual PID settings
<MTM400Configuration> → <Streams> → <Stream> → <PIDS>
Path
Child Element
<PID>
Table 2−3: PID Parameters
Parameter
Identity
Description
PP1
PID bit rate limit and missing test integration count
PP11
Max PCR overall jitter
PP12
Maximum PCR frequency offset
PP13
Maximum PCR frequency drift rate
PP14
PCR frequency drift rate integration count
PP16
Minimum bit rate permitted for this PID
PP17
Partial Reception PCR max repetition interval
ISDB_T
Test Parameters - Parameter Reference
Nominal
Maximum
1
60
Nominal
Maximum
25000
200000000
Nominal
Maximum
810
30000
Nominal
Maximum
75
10000
Nominal
Maximum
25
250
Nominal
Maximum
1000
80000
Nominal
Maximum
260
5000
Minimum
Units
1
integer > 0
Minimum
Units
250
ns
Minimum
Units
50
Hz
Minimum
Units
10
mHz/s
Minimum
Units
1
integer > 0
Minimum
Units
1000
ms
Minimum
Units
0
ms
2−177
Need help?