12611 (Hex: 0x3143)
3.6a EIT Actual
Description:
Applicable Standards:
Associated Parameter(s)
PS26
PS27
PS28
PS32
PS33
PS34
12612 (Hex: 0x3144)
3.6b EIT Other
Description:
Applicable Standards:
Associated Parameter(s)
PS29
PS30
PS31
PS35
PS36
PS37
12624 (Hex: 0x3150)
2.3a PCR Repetition
Description:
Applicable Standards:
Associated Parameter(s)
PP17
PP2
MTM400 MPEG Transport Stream Monitor Technical Reference
Test Parameters - Event Identity to Test Name
Section '0' with table_id = 0x4E (EIT-P, actual transport stream) not
present on PID 0x0012 for more than 2s. Section '1' with table_id =
0x4E (EIT-F, actual transport stream) not present on PID 0x0012 for
more than 2s Sections with table_ids other than in the range 0x4E -
0x6F or 0x72 found on PID 0x0012. Any two sections with table_id =
0x4E (EIT-P/F, actual transport stream) occur on PID 0x0012 within a
specified value (25ms or lower).
DVB, Chinese
EIT actual PF minimum section repetition interval
EIT actual PF maximum repetition interval
EIT actual PF obsolescence count
EIT actual schedule minimum section repetition interval
EIT actual schedule maximum repetition interval
EIT actual schedule obsolescence count
Interval between sections '0' with table_id = 0x4F (EIT-P, other
transport stream) on PID 0x0012 longer than a specified value (10s or
higher). Interval between sections '1' with table_id = 0x4F (EIT-F, other
transport stream) on PID 0x0012 longer than a specified value (10s or
higher).
DVB, ISDB, Chinese
EIT other PF minimum section repetition interval
EIT other PF maximum repetition interval
EIT other PF obsolescence count
EIT other schedule min section repetition interval
EIT other schedule max repetition interval
EIT other schedule obsolescence count
PCR Error Timer
MPEG, DVB, ATSC, ISDB, Chinese, DCII
Partial Reception PCR max repetition interval
PCR max repetition interval
2−61