Starting And Shutting Down The Xentry Connect; Battery Compartment - Mercedes-Benz XENTRY Kit 2 User Manual

Table of Contents

Advertisement

The following functions are available:
• Change (W)LAN mode
• Release device – after additional confirmation request
• Start network self-test
• Switch off device – after additional confirmation request
• Activate / deactivate Automatic Quick Test Routine (AKT)
Back/cancel button
Back:
press button < 2 seconds
Cancel: press button > 2 seconds
Confirm button: OK / Yes
When the device is switched on ▸ start the initial startup
process with the USB memory stick
When the device is switched off ▸ Start update/recovery
Depending on precondition, the back/cancel button and
confirmation button combination (pressed for two seconds)
triggers different actions:
• When the device is switched on, the initial startup
process starts:
When the device is switched on, pressing the cancel and
confirmation buttons at the same time for two seconds
starts the initial startup process. Details can be found in
the chapter 5 Initial Startup and Configuration.
• When the device is switched off, update/recovery
starts:
When the device is switched off, pressing the cancel and
confirmation buttons at the same time for two seconds
switches the device on and starts the update process.
Details can be found in the chapter 11 Update & Recovery.

6.4 Starting and Shutting Down the XENTRY Connect

A XENTRY Connect is started by pressing its operating
buttons or by connecting an OBD power supply. The device is
fully booted when the "Ready" icon
on the display. Shutting a XENTRY Connect down to standby
is carried out using the operating menu function button.
If a user is still connected to this XENTRY Connect at this
User Guide XENTRY Kit 2, XENTRY Kit MT 2, XENTRY Connect
Key combination
is continually shown
point in time, this visual connection is ended in a controlled
manner with a corresponding notice message. If a XENTRY
Connect is shut down unexpectedly, e.g. due to a crash or
the absence of a power supply, currently connected users
receive an error message.

6.5 Battery Compartment

The cover of the rechargeable battery compartment can be
opened (by releasing four screws) to exchange the recharge-
able battery if necessary. Remove the rubber bumper to do
this.
This compartment contains a rechargeable lithium-ion bat-
tery block. In addition to cells, electronic protection devices
and intelligent battery management, it also has non-elec-
tronic protection devices and mechanical components.
The battery has a rated voltage of 7.2 volts and a maximum
capacity of 4.5 Ah.
Note: Please do not frequently remove the rechargeable
battery! Please follow the instructions. Do not open the
battery compartment or exchange the rechargeable battery
while the XENTRY Connect is connected to a vehicle or a
diagnostic process is running. Only open the rechargeab-
le battery compartment after consulting the responsible
support.
1
2
Daimler AG, Item No. 6511 9538 02, Last updated: 09/2014
Figure 41: XENTRY Connect
battery compartment
Figure 42: Compartment for
battery pack
Figure 43: Inserting the rechargeable
battery
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xentry kit mt 2Xentry connectXentry tab 2

Table of Contents