Cabled Online Mode; Mixed Operation; Minimum Technical Requirements And Restrictions On Use Of A Standard Pc - Mercedes-Benz XENTRY Kit 2 User Manual

Table of Contents

Advertisement

4.1.3 Cabled online mode

In the event that you require an online connection to back-
end systems, but you want to establish the connection
between XENTRY Tab 2 and XENTRY Connect independent
of the workshop infrastructure, a new mode is now availab-
le. It requires using the WLAN workshop mode and thereby
an online connection of the XENTRY Tab 2. To setup the
cabled online mode, connect the XENTRY Tab 2 and XENTRY
Connect to each other using an Ethernet cable and click on
the XENTRY Connect tile in XENTRY Control. This automati-
cally configures thenew mode.
Figure 9: Cabled online mode

4.1.4 Mixed Operation

• WLAN and LAN combined
Workshop mode in mixed operation: E.g. XENTRY Connect
in the WLAN, XENTRY Tab 2 in the LAN. Devices are linked
to each other via the workshop network and are connected
to the back-end systems.
Figure 10: Combined WLAN and LAN
The following connection logic is not possible:
Figure 11: Connection mode not possible
The "serial connection" familiar from Star Diagnosis systems,
i.e. the connection of XENTRY Connect and XENTRY Tab 2 to
the workshop infrastructure via LAN and connection of the
XENTRY Tab 2 via LAN, is not possible.
12
4.2 Minimum technical requirements and restrictions
on use of a standard PC
A standard PC may be used as an operating and display
unit instead of the XENTRY Tab 2. You are entirely at liberty
to choose the PC manufacturer and model, but must observe
certain minimum requirements.
Minimum requirements:
Operating system:
Windows 7 or Windows 8.1(recom-
mendation: Professional 32-bit)
Processor:
1.1 GHz Dual-Core
Hard disk:
At least 30 GB available
RAM:
2 GB
USB ports:
At least 2 x USB 2.0 (for external
BD drive) or integrated BD drive
Network:
LAN and WLAN
Display:
Recommended minimum size: 13.3"
Recommended minimum resolution:
1366*768 pixels
Virus scanner:
Recommended
.net Framework version 4.0
Note: You will find the current recommendations
for the minimum requirements of a standard PC in the
Mercedes-Benz After Sales Portal.
Restrictions on use of a standard PC:
• No XENTRY HMS 990 USB Measurement Technology
or chip card reader can be used; the product support
is also limited.