WALL HUNG ELECTRIC BOILER
ATTACK®
ELECTRIC EXCELLENT
INSTRUCTIONS FOR USE
W W W . A T T A C K . S K

Advertisement

Table of Contents
loading

Summary of Contents for ATTACK ELECTRIC 08

  • Page 1 WALL HUNG ELECTRIC BOILER ATTACK® ELECTRIC EXCELLENT INSTRUCTIONS FOR USE W W W . A T T A C K . S K...
  • Page 3: Table Of Contents

    ..3 Dear customer, You have bought a modern product – the direct heated electric boiler ELECTRIC EXCELLENT from the company Transport and warehousing ..31 ATTACK, s.r.o., Slovak Republic. We believe that our...
  • Page 4: General Information

    ®  Boilers ATTACK are electric, using water for heating. It  step less regulation of boiler output with continuous is electric wall-hung appliance determined for heating switching on/off heating elements economic of family houses or flaks with heat loss to 22,5 kW.
  • Page 5: Mounting

    safety units or elements in the boiler!!!  Mounting of the boiler could be carried out only by authorized company or persons.  If the guarantee list is not filling fully, it is not valid  On the boiler and 100mm before the boiler there is If you take the boiler from the colder environment not allowed a placement of things from flammable to the warmer one (for example if the outside...
  • Page 6: Main Dimensions

    1.4 Main dimensions Dimensions in mm.
  • Page 7: Technical Data

    1.5 Technical data ELECTRIC 08 ELECTRIC 15 ELECTRIC 24 Boiler type Unit EXCELLENT EXCELLENT EXCELLENT Electric parameters Total electric input 22,5 Nominal heating output 22,5 Heater power output 3x2,5 2x3x2,5 3x3x2,5 Nominal current 3x12 / 1x36 3x24 3x36 Electric network*...
  • Page 8: Main Parts

    1.6 Main parts boiler heating sensor emergency thermostat boiler body G3/8” deaerate valve mode relay mode sanitary water heating elements control unit holder reservoir of emergency thermostat display insulation of boiler touch control buttons body control unit frame of the boiler control pane switchboard X2 thermomanometer...
  • Page 9: Description Of Functions

    inlet of heating water blow off valve of the boiler G 3/4” (cold) body outlet of heating wate outlet of safety valve blow off valve of th (warm) G 3/4” pump and rules ČSN EN and IEC. The safety of the boiler, energy ...
  • Page 10: Protection Function Of The Boiler

      signal of relay lightening in the second level The control unit has a protection against below and potentional free switcher over voltage   The control unit is protected by system Watch-Dog- HDO (mass remote control) signal potentional free switcher Timer with time 512 ms against its processor “blocking”.
  • Page 11: Circuit Diagram

    1.8 Circuit diagram Circuit diagram for connection of the boiler EK18K, EK24K to supply electrical net 3x230V/400V...
  • Page 15 Circuit diagram TUV ZOV (sanitary water, storage water tank) of the boiler EK 24K...
  • Page 16: Control Panel

    2. Maintenance Control panel information display --0 C --0 C change of the requested 22,5 kW parameter + - temperature setting in the reference room - sanitary water temperature setting - information about instantaneous stage - selection confirmation change of the requested - parameters enter parameter - going to mode STAND-BY...
  • Page 17 Display - Basic information displayed instantaneous temperature of sanitary water in the storage water tank instantaneous temperature (only if the boiler has TUV (sanitary water) mode of heating water and TUV (sanitary water) sensor connected) instantaneous temperature in referring room (in case of reffering room sensor connection) 55 C 21 C...
  • Page 18: Switch On/Off

    2.2 The boiler switching ON/OFF Use the switcher 0/1 placed on the right corner of bottom side of the boiler (see the picture 1.6 Main parts) On the display there is displayed introductory information after boiler's switching on. Example:: - electric boiler ELECTRIC EXCELLENT with output 22,5 kW E - KOMFORT: 22,5 kW TUV: NE VER.1.20...
  • Page 19 Without the room thermostat connected With the room sensor connected (on the display there is marked by the symbol In case that the room sensor is connected (the order number of set is 4050485) the boiler is heating according to the temperature in a reference room with hysteresis 1 °C.
  • Page 20: Operation Service Utility Water (Sanitary Water)

    Below mentioned equitermic curves are calculated for room reference temperature 20 °C. equitermic curves of control panel curve No. curve No. curve No. curve No. curve No. curve No. curve No. curve No. curve No. curve No. outside temperature (°C) Temperature of heating water for heating will be With connection of TUV sensor automatically calculated on the basis of the outdoor...
  • Page 21: Setting Of Boiler Parameters

    The boiler is controlled by potential-free signal ON/OFF  the boiler will hold the temperature set in the storage connected to the clamps of TUV mode. In case of the water with hysteresis set by the parameter 21 in a scale request for TUV/sanitary water heating “ON”...
  • Page 22 Min. Parameter Information/value Factory Importance Setting value Autorization version of marking displayed in English setting the boiler Setting of heating water tempeature, going to HW setting "summer" opeation mode under 30 °C (symbol of 30 to 80, step 1 User summer = tap) Setting of sanitary (domestic hot water) tempeature, DHW setting...
  • Page 23 Function and its setting Remarks: In case that the request for heating of sanitary water is terminated in winter operation mode there is The electric boiler is equipped with several useful functions activated time pump running out set previously 1 min. into assuring its comfort and economical operation.
  • Page 24 P8- Equithermic regulation (NO, 1 to 10) This parameter could be set only by authorized service technique!  this function actives the boiler regulation on the basis This constant could be changed only of dependency of heating water temperature calculated according to producer instructions! and outdoor temperature according to an equitermic curve and its movement.
  • Page 25 This parameter could be set only by  Value 0-half the max. power output, a step by the set authorized service technique! value of parameter P35. Operation of the boiler in HT is possible only on the basis of permission of This parameter could be set only by official electricity network distributor! authorized service technique!
  • Page 26 For this possibility of remote GSM control of the boiler it is necessary to buy a GSM model! P35 - Heating rod power output selection GSM module works only in the nets with standartized GSM protocol.  A heating rod power output can be selected by selecting this parameter the actual power output will be shown on the display on the basis of this value.
  • Page 27: Breakdowns

    2.5. Errors/breakdowns Table of errors/breakdowns displayed Archive of Critical Importance Reset Possible cause Elimination breakdowns defect symbol Invalid sensor of heating water Automatic Invalid sensor or cable fault. Call service Err3 (shunt fault). Invalid sensor of TUV Automatic Invalid sensor or cable fault. Call service Err3 temperature (shunt fault)
  • Page 28: Installation

    wall has to be in accordance with normal environment 3.Installation AA5/AB5 according to ČSN 33 2000 3. 3.1.Norms and regulations It is not allowed for boilers to be installed in bathrooms, For safety operation, projection, mounting, operation and wash rooms, shower rooms in place 0, 1, 2, 3 according to service of boiler is valid below mentioned norms and the rule ČSN 33 20007701.
  • Page 29: Installation Of The Room Thermostat

    Other bushings PG9, PG7 are for other signals of the necessary to screw or to fix another way to the cover of room thermostat and the 3-ways valve. the boiler to avoid its dismantling. For GSM modem 3.4.2 Installation of the room thermostat mounting use inlets on the upper cover of the boiler.
  • Page 30: Marking Of Working Scale

    Graph Dependency of expansion vessel volume on volume of heating system for thermal drop 80/60 °C. pressure of heating system 2 bar pressure of heating pressure of heating system 1 bar system 1 bar pressure of heating system 0,5 bar volume of heating system (l) The graph is determined for thermal drop 80/60 °C and putting the boiler into operation.
  • Page 31: Maintenance

    dependent on the demand of regulation and the safety is able to clean surface of the cover with detergents and traffic and heat systém. control operation modes or fill heating water to the system checked by water pressure dawn according to the value on ...
  • Page 32: Claims

    8. Claims 9. Way of liquidation Solid waste recycling If you have functional and face defects on your boiler,  molid board please do not repair it by yourselves.  PE bags, polystyrene, binding tapes  Please apply your claim by the company which put your ...
  • Page 33: Installation Of Room Thermostat

    Control unit and TUV (sanitary water) mode diagram 10.2. a) control unit b) relays mode TUV (sanitary water) mode...
  • Page 34 Boiler commissioning certificate Data of the customer: (legibly) Serial number: ..........Name and surname: Date of commission: ......................... Service organization: Street: ..............ZIP code, town: ......................... Stamp, signature Tel.: ..............Obligatory service inspection after the 1st year of operation Date: ......
  • Page 36 Výrobca ATTACK, s.r.o. si vyhradzuje právo technických zmien výrobkov bez predchádzajúceho upo- zornenia. • ATTACK, s.r.o. producer reserves the right to change technical parameters and dimensions of boilers without previous warning. • Der Hersteller ATTACK, s.r.o. behält sich das Recht der technischen Veräderungen an Produkten ohne eine vorige Warnung.