Function and its setting
The electric boiler is equipped with several useful functions
assuring its comfort and economical operation. Putting the
boiler into operation it is necessary to set carefully boiler´s
function by setting of parameters for right function of the
boiler and heating system. On the lower line of display
there is "help" lighted for easy operation and setting of the
parameter.
Setting of parameters
Press shortly
and now you are in the display for setting
the parameters. Use
+
parameter which you want to change. It is necessary to
press
for editing of the parameter (editing is shown by
±on the right lower corner), now you can change the value
of the parameter setting by
parameter by
, or
during setting the phone numbers
or PIN code (parameters 29, 30, 31, 32).
Value set or chosen by you is necessary to confirm by
its saving (> is blinking shortly).Now you are able to
change the next parameter by pressing
approximately 10 s and the boiler goes automatically back
to the basic display.
Going back to the factory setting
In case that you set the parameter wrongly or not
requested, it is possible to go back to the factory setting as
follows: Switch off the boiler using the main switcher and
press in one time
display there is "RESET TOVARNICH PARAMETRU" lighted
and after O.K., the factory parameters are in the factory
setting.
Description of parameters
Heating water temperature, sanitary water temperature
and temperature in a reference room were described in
previous chapters.
P1- Language (CZ, EN,FR,SK,DE)
setting of language for communication of the boiler on
its display and for sending SMS about breakdowns (GSM
mode)
CZ Czech language, EN English language, FR French,
SK Slovak, DE German language
P2- Possibility of permanent lighting of display
(Y/N)
Y the display is lighting permanently
N the display is lighting only during its activation by
pressing of a button, for 30 s
Remarks: if you press firstly and shortly, editing is not
in a process only the display is lighting.
P3-Pump time running out (time, temperature)
Setting of time running out after termination of request
for heating
Time for time pump running out with time set by the
parameter P4
Temperature for temperature pump running out with
temperature set by the parameter P5.
P4-Time pump running out (1- 30 s)
Time setting for pump running out after termination of
request for heating.
,
and list the number of
-
or
, or move in the
-
+
or
, or wait
-
+
and switch on the boiler. On the
Remarks: In case that the request for heating of sanitary
water is terminated in winter operation mode there is
activated time pump running out set previously 1 min. into
heating system. In case of the summer operation mode
there is time running out 1 min. into storage water tank.
P5-Temperature pump running out (25 - 70° C)
temperature setting , if the temperature will be over
the temperature set, the pump will be in a operation.
Remarks: In case that the request for hating of sanitary
water is terminated in winter operation mode there is
activated time pump running out set previously 1 min. into
heating system. In case of the summer operation mode
there is time running out 1 min. into storage water tank.
P6-Temperature limit for underfloor heating (NO,
25 - 55°)
limitation of maximal temperature of heating water with
for
using the boiler for underfloor heating without the
priority of heating water set.
Remarks: In case of active equithermic regulation the
boiler will "cut" by this temperature the equitermic curve
set.
Always it is necessary to assure the
protection of underfloor heating system
circle against overheating using the
external equipment (for example mixture
valve or limit thermostat for underfloor
heating, its clamps are able to be
connected to the control unit on the
position of emergency thermostat of
underfloor heating).
Remarks: The boiler has the clamp for underfloor heating
thermostat connection (on the control unit there is
marking "FLOOR"). In case that temperature is higher than
the temperature set by this thermostat then control unit
will disconnect or output levels and stop the pump
operation.
We recommend you installation of this thermostat to avoid
overheating of undefloor heating system
P7-Antifrost protection (Y/N)
This function protects the boiler against boiler icing.
In case that the boiler water temperature falls down
below 5° C the boiler will switch on the pump
operation and will heat to 15 ° C. After that the boiler
goes back to the stage before antifrost protection
starting. The pump running out is activated for 1 min.
This function is active in all the modes.
Y function is active according above mentioned steps.
N function is not active (for example in systems there
are the antifreeze liquid additives.
In case of deactivation of this function
there is a threat of property damages.
The boiler is not able to protect rooms
there is the temperature lower than the
temperature in the room there is the
boiler placed (for example the boiler is
placed in a cellar and the coldest room is in
an attic.).