Part 3. Repair
10. Loosen and remove the screw (1) that fixes the cover (2).
11. Remove the cover (1) from the unit.
1. Screw
12. Loosen and remove the screw (1) that fixes the piping cover (2).
13. Remove the piping cover (2) from the unit.
1. Screw
14. Loosen the thermistor fixing plate (2).
15. Slightly twist the right side of the thermistor fixing plate (2), and gently pull the left side of the thermistor fixing plate (2) until it
unlatches.
16. Slide the thermistor fixing plate (2) until it detaches from the right side plate (4).
17. Turn over the thermistor fixing plate (2) and unlatch the thermistor cover.
18. Remove thermistor R1T (1) from the thermistor fixing plate (2).
19. Remove the thermistor fixing plate (2).
20. Guide the thermistor R1T (1) into the unit.
21. Loosen and remove the 5 screws (3) that fix the right side plate (4).
22. Remove the right side plate (4) from the unit.
22/08/16
|