Known Limitations;
JIRA#
Subject
RSS-120
Overlapping names
RSS-136
VSX 5000-8000
Interoperability
RSS-141
RMX 2000
VNGR-4291
Interoperability
RSS-142
RMX 2000
Interoperability
RSS-137
ViewStation
Interoperability
RSS-121
IVRs
RSS-129
Maximum frame
rate for recording
and playback
RSS-130
Point to Point
recording
RSS-157
Embedded
Multipoint on the
VSX
RSS-148
Sony HG90
version:
2.11 Beta
Interoperability
RSS-153
H239 Content
resolution
RSS-154
Econf integration
RSS-147
Aethra X7
integration
RSS-301
RMX 2000
integration
RSS-391
2CIF/2SIF support
RSS-276
LAN Setting
RSS-373
Stereo support
RSS-256
DOC2207A RSS 2000 V3.0 Getting Started guide - Release Note - Final - February 26, 2008.doc
The monitor screen displays an overlapping names of VSX8000 and RSS in a MGC meeting
room
The RSS 2000 support the VSX 5000-8000 when the VSX is set to motion (Not Sharpness
nor Promotion)
The RMX 2000 connects secondary to the RSS 2000 in the rate of 64Kbps (No support for
G.728 at the RMX 2000 (RMX 2000 connect to the HDX and VSX at G.729A in 64K which is
not supported by the RSS 2000)) – recording at this low video rate is not recommended in
any case.
While RSS2000 is connected to RMX2000 in SIF when the RMX is set to Sharpness , an
archive of it is tagged as H.264 SD.
ViewStation show blue then green screen at the beginning of a connection to RSS2000
When recording an IVR message – it's require to add additional 1 second of silence for each
recording, to prevent message truncation with VSX and Viewstations
Maximum frame rate for recording and playback in the recording room is 20 fps in H.264
and 25 fps in H.261/H.263
HD is not supported in Point to Point recording. When using an HD endpoint it's
recommended to dial directly to the recording room [RSS2000 Prefix][Recording Room
Prefix] and not to connect to the Recording room via the H323 Menu.
When recording a multipoint on a VSX – first connect the endpoint to the VSX and only than
connect to the RSS 2000
Sony HG90 can connect in HD only. The RSS 2000 menu is in CIF (Not in HD) as so the
HG 90 will connect as secondary.
The RSS 2000 support H263 content (Not H264) – as most endpoint currently support H263
content – in order to prevent interoperability issue, when playing back the stream (In H323)
the RSS will not support H264 content (Lower common nominator)
France Telecom eConf can not get video from RSS
Connect Aethra X7 to RSS2000 @1920K ,the X7 sends 720p, but receives CIF from the
RSS2000.
RSS2000 can only support CIF/SIF for menu .
HD Recording with the RMX 2000 is supported only on full screen layout
RSS can not encode 2CIF/2SIF as a standard resolution when transforming to WMV file ,
the WMV file is not correct resolution , just keep same scale with 2CIF or 2SIF , so the
anemographic video will be showed on PC .
Disable promotion on the VSX when working with the VSX
The same LAN Speed need to be forced on the RSS side and in the switch side.
SIREN 22 Stereo is supported for H323 Playback. When playing the archive using windows
media player - the archive will be played in mono.
RSS takes a while to respond to a "stop recording" action at endpoint , can not end and
play IVR immediately .