Technical Data; Cables - Fasel Elektronik FCU2000 Series Installation Instructions Manual

Sauna control
Hide thumbs Also See for FCU2000 Series:
Table of Contents

Advertisement

2

Technical Data

2.1

Cables

Use of
inappropriate
cables –
Electric
potential
Designation
Power supply cables
230 / 400V cables for
supply to oven,
evaporator, fan, light etc.
Signal cables for sensors
Connecting cable
Control device to
operating element or
interior display
Specification of the patch
cable
Conduit for patch cable
Table 1: Technical data – cables
Installation instructions Sauna control Series FCU2x00/FCU3x00/FCU4x00 / Version V 2.18
DANGER!
Danger to life due to electric potential
Use of inappropriate cables can lead to short circuits and subsequent
fires.
Damage to the insulation can be dangerous to life.
Therefore:
– All the cables, which lead to the sauna, must be designed for at least
150 ° C.
– Use cables as per specifications in Table 1 and electrical circuit
diagram (see annexure). The specified cross sections are designed
for copper cables. In case of aluminum cables the cross sections
should be appropriately increased.
– The cross sections can increase due to the length of the cables, the
type of cable laying or special regulations.
Type
FCU2x00
Type / Cross
H07RN-FG2,5 (heavy rubber hose 2,5 mm
section /
Power supply cables must be polychloroprene-coated and
Number of
should not be lighter than heavy polychloroprene-coated
leads
flexible cables.
Type
Heat resistant, at least 150 ° C
Cross section
→ See electrical circuit diagram.
Number of
leads
Type
In case of longer distances: LiYCY
(flexible, shielded cable)
Within the cabin: heat resistant,
minimum 150 ° C
Cross section
→ See electrical circuit diagram.
Number of
leads
The patch cable can be delivered with a standard length of 5 or 10m. If
another length is desired then the cable must be configured by the
electrician. Another option would be to bridge a stretch by installing two
network sockets (CAT 5).
Minimum CAT 5, minimum AWG26
Plugs should have no rubber covering over the locking mechanism
Pin 1 to Pin 1 cable configuration (straight through)
Min. M32 (inner diameter min. 24mm), smallest bending radius 30 cm
Technical Data
FCU3x00
FCU4x00
2
)
9

Advertisement

Table of Contents