Technical Specifications - Siemens SINAMICS G120 Hardware Installation Manual

Power module
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Technical specifications

Common performance ratings of the Power Module
Table 6- 1
Feature
Line operating voltage
Input frequency
Power factor λ
Overload capability for
base load (HO)
0.37 kW ... 75 kW
Overload capability for
base load (HO)
90 kW ... 200 kW
Overload capability for
base load (LO)
7.5 kW ... 90 kW
Overload capability for
base load (LO)
110 kW ... 250 kW
Inrush current
Pulse frequency
Electromagnetic
compatibility
Braking
Protection level
Temperature range
without derating (HO)
Temperature range
without derating (LO)
Power Module PM240
Hardware Installation Manual, 07/2009, A5E00807525B AD
Performance ratings
Specification
3 AC 380 V ... 480 V ± 10%
The permissible voltage depends on the operational altitude
47 Hz ... 63 Hz
0.7 ... 0.85
1.5 x Base-load output current (150% overload) for 57 s every 300 s
2 x Base-load output current (200% overload) for 3 s every 300 s
1.36 x Base-load output current (136% overload) for 57 s every 300 s
1.6 x Base-load output current (160% overload) for 3 s every 300 s
1.1 x Base-load output current (110% overload) for 57 s every 300 s
1.5 x Base-load output current (150% overload) for 3 s every 300 s
1.1 x Base-load output current (136% overload) for 59 s every 300 s
1.5 x Base-load output current (150% overload) for 1 s every 300 s
Less than rated input current
4 kHz standard for 0.37 kW ... 75 kW (HO)
2 kHz standard for 90 kW ... 200 kW (HO)
The pulse frequency can be changed manually in 2 kHz steps.
Increasing the pulse frequencies above standard leads to an output
current reduction.
Optional Class A filters available according to EN 55011
DC braking, Compound braking, Dynamic braking with integrated chopper
IP20 or IPXXB
IPXXB protection is ensured with the Power Module FSGX
(HO 132 kW ... 200 kW) in conjunction with the Control Units CU240E
and CU230P-2.
0.37 kW ... 110 kW
0 °C ... +50 °C (14 °F ... 122 °F)
132 kW ... 200 kW
0 °C ... +40 °C (32 °F ... 104 °F)
0.37 kW ... 132 kW
0 °C ... +40 °C (14 °F ... 104 °F)
6