Feature
Weight
Possible as base
component
Table 7- 19
Technical specifications of the sine-wave filters (table 4 of 5)
Feature
MLFB of the sine-wave
filter
MLFB of the suitable Power
Module
dv/dt limiting
Power loss at 50 Hz
Motor connection
Connection to Power
Module
Degree of protection
Overall dimensions
Width
Height
Depth
Installation clearance
Top
Bottom
Side
Fixing dimensions
Width
Depth
Fixing screw
Weight
Possible as base
component
Power Module PM240
Hardware Installation Manual, 07/2009, A5E00807525B AD
Suitable for Power Module with rated power (HO) of
15 kW ... 18.5 kW
24 kg
Suitable for Power Module with rated power (HO) of
45 kW ... 55 kW
6SL3202-0AE31-5SA0
6SL3224-0BE34-5 . A0
180 W
Screw terminals 50 ... 150 mm²
Screw terminals 50 ... 150 mm²
IP00 without terminal cover, IP20 with terminal cover
350 mm
440 mm
305 mm
320 mm
255 mm
4 × M8
63 kg
22 kW
FSD
34 kg
no
75 kW
FSF
6SL3202-0AE31-8SA0
6SL3224-0BE35-5 . A0
≤ 500 V/µs
190 W
350 mm
468 mm
305 mm
100 mm
-
100 mm
320 mm
155 mm
80 kg
no
Accessories
7.1 Reactor and filter
30 kW ... 37 kW
FSE
45 kg
90 kW ... 110 kW
6SL3000-2CE32-3AA0
6SL3224-0BE38-8UA0
6SL3224-0BE41-1UA0
200 W
Flat connector for M10 cable
lug
Flat connector for M10 cable
lug
IP00
620 mm
320 mm
300 mm
225 mm and 150 mm
280 mm
6 × M10
124 kg
99