Technical Specifications - Siemens Sinamics G120 Operating Instructions Manual

Smart access
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

Additional information

7.3 Technical specifications

7.3
Technical specifications
Feature
Article number
Net weight
Gross weight
Operating ambient temperature
Transportation and storage ambient temperature
Extreme temperature range
Relative humidity
Rated voltage
Wireless technology and working frequency
Wireless modulation type
Antenna gain
Maximum radio frequency output power
Protection
Shock and vibration
Directives and standards
EIRP means effective isotropic radiated power.
1)
Changes or modifications made to this device not expressly approved by SIEMENS may void the FCC authorization to
2)
operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two condi-
tions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, in-
cluding interference that may cause undesired operation.
This device must not be protected against harmful interference and it may not cause interference in authorized systems
3)
(see below for corresponding text written in Portuguese).
58
Description
6SL3255-0AA00-5AA0
87.5 g
109.7 g
0 °C ... 50 °C
-40 °C ... 70 °C
-10 °C ... 60 °C
< 95%, without condensation
15 V DC
Wi-Fi 2400MHz ... 2483.5MHz
802.11 b/g
1.9 dBi
17 dBm (EIRP
)
1)
Depending upon the inverter IP rating to a maximum of IP55/UL
Type 12
Long-term storage in the transport packaging according to Class
1M2 according to EN 60721-3-1: 1997
Transport in the transport packaging according to Class 2M3 ac-
cording to EN 60721-3-2: 1997
Vibration in operation according to Class 3M1 according to EN
60721-3-3: 1995
CE, FCC
, SRRC, WPC, ANATEL
2)
Radio Equipment Directive 2014/53/EU
SINAMICS G120 Smart Access is in compliance with Directive
2014/53/EU.
Electromagnetic compatibility
SINAMICS G120 Smart Access in compliance with IEC 61800-3 is
suitable for EMI second industrial environment Category C2 and
EMS second industrial environment.
3)
SINAMICS G120 Smart Access
Operating Instructions, 04/2018, A5E43332487

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents