b.
Auto Cooling or Heating RH Group
Maintains room temp. at desired level by selecting between Cooling or Heating Modes.
o
(RT - SPT) [
c]
+3
+2
+1
0
-1
-2
-3
Auto Heat Mode
ON
COMP
OFF
& OFAN
ON
HE1
OFF
ON
HE2
OFF
H/M/L
L
IFAN
OFF
30 sec
(1)
OFF
RV
11.11
Dry Mode
11.11.1
Dry, ST or RC Group or P2000 Model with Any Group Settings
Mode:
DRY
Temp: Selected desired temperature
Fan:
LOW (automatically selected by software)
Timer: Any
I-FEEL: Any
Control function
Reduce room humidity with minimum temp. fluctuations by operating in Cool Mode with
LOW speed IFAN.
SM PXD 1-E.3 GB
Auto Cool Mode
> 3 min
(2)
CONTENT
CONTROL SYSTEM
Auto Heat Mode
> 3 min
(2)
11-21