5.13
PXD18 GC18 3PH R410A
5.13.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
(1)
15
(1)
20
25
30
35
40
46
LEGEND
TC
Total Cooling Capacity, kW
SC
Sensible Capacity, kW
PI
Power Input, kW
WB –
Wet Bulb Temp., (
DB
Dry Bulb Temp., (
ID
Indoor
OU
Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).
SM PXD 1-E.3 GB
PERFORMANCE DATA & PRESSURE CURVES
ENTERING AIR WB/DB ID COIL ( °C)
DATA
15/21
5.80
TC
4.09
SC
1.25
PI
TC
5.61
4.01
SC
1.36
PI
TC
5.31
SC
3.91
1.47
PI
TC
4.96
SC
3.79
1.59
PI
TC
4.59
3.60
SC
1.71
PI
TC
4.18
3.39
SC
1.85
PI
TC
3.62
3.13
SC
2.02
PI
o
C)
o
C)
CONTENT
17/24
19/27
21/29
6.00
6.15
4.27
4.43
1.26
1.26
5.91
6.10
4.23
4.41
1.37
1.37
5.73
6.02
4.15
4.37
1.48
1.49
5.40
5.84
4.02
4.28
1.63
1.61
4.99
5.50
3.86
4.18
1.77
1.74
4.55
4.96
3.65
3.95
1.88
1.91
3.96
4.36
3.35
3.61
2.05
2.10
23/32
6.29
6.39
4.55
4.63
1.26
1.27
6.24
6.38
4.53
4.62
1.38
1.38
6.21
6.36
4.50
4.58
1.50
1.51
6.05
6.22
4.40
4.49
1.64
1.65
5.78
6.05
4.30
4.38
1.78
1.79
5.43
5.71
4.08
4.16
1.93
1.95
4.82
5.19
3.73
3.81
2.13
2.15
5-17