5.10
PXD18 GC18 R410A
5.10.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
(1)
15
(1)
20
25
30
35
40
46
LEGEND
TC
Total Cooling Capacity, kW
SC
Sensible Capacity, kW
PI
Power Input, kW
WB –
Wet Bulb Temp., (
DB
Dry Bulb Temp., (
ID
Indoor
OU
Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).
SM PXD 1-E.3 GB
PERFORMANCE DATA & PRESSURE CURVES
ENTERING AIR WB/DB ID COIL ( °C)
DATA
15/21
TC
5.80
3.94
SC
1.29
PI
TC
5.61
SC
3.86
1.40
PI
TC
5.31
SC
3.76
1.51
PI
4.96
TC
SC
3.64
PI
1.63
4.59
TC
3.46
SC
1.76
PI
TC
4.18
3.26
SC
1.90
PI
TC
3.62
3.01
SC
PI
2.08
o
C)
o
C)
CONTENT
17/24
19/27
21/29
6.00
6.15
4.11
4.27
1.29
1.30
5.91
6.10
4.07
4.24
1.41
1.41
5.73
6.02
3.99
4.21
1.52
1.53
5.40
5.84
3.87
4.11
1.67
1.66
4.99
5.50
3.71
4.02
1.82
1.79
4.55
4.96
3.51
3.80
1.93
1.96
3.96
4.36
3.22
3.47
2.11
2.16
23/32
6.29
6.39
4.37
4.45
1.30
1.31
6.24
6.38
4.36
4.44
1.42
1.42
6.21
6.36
4.33
4.41
1.54
1.56
6.05
6.22
4.24
4.32
1.68
1.70
5.78
6.05
4.14
4.22
1.83
1.84
5.43
5.71
3.92
4.00
1.99
2.01
4.82
5.19
3.59
3.67
2.19
2.21
5-13