Electra PXD912 Service Manual page 102

Pxd series r410a
Table of Contents

Advertisement

CONTROL SYSTEM
Fail condition:
0 sec - STAND-BY is turned ON
3 sec - STAND-BY, OPER, TIMER and FILTER are turned ON
When the timing reset test is completed, the next test will start automatically.
i.
STEP 8: MEMORY TEST (EEPROM)
The test purpose is to check if the memory is functioning correctly. The test result
is reported by using the STAND-BY and FILTER LEDS:
LED Indicator
STAND-BY LED
FILTER LED
AT THIS POINT THE SELF-TEST IS COMPLETED.
In order to terminate Self-Test mode the User can change the unit setting from COOL
Mode, LOW FAN to COOL Mode, MED FAN or to wait without using the remote control
for 60 sec.
Values of Sensors Temperature VS. Voltage (DC)
Temp.
Voltage
(°C)
(V)
-20
4,554
-19
4,529
-18
4,502
-17
4,475
-16
4.446
-15
4.417
-14
4.386
-13
4.354
-12
4.322
-11
4.287
-10
4.252
-9
4.216
-8
4.178
-7
4.14
-6
4.1
-5
4.059
-4
4.017
-3
3.974
-2
3.93
-1
3.885
0
3.839
1
3.792
11-36
Condition for LED to be ON
Test passed
Test failed
Temp.
Voltage
Temp.
(°C)
(V)
(°C)
2
3.744
3
3.695
4
3.646
5
3.595
6
3.544
7
3.492
8
3.439
9
3.386
10
3.332
11
3.278
12
3.223
13
3.168
14
3.113
15
3.058
16
3.002
17
2.946
18
2.89
19
2.833
20
2.777
21
2.722
22
2.666
23
2.61
CONTENT
Voltage
Temp.
(V)
(°C)
24
2.555
46
25
2.5
47
26
2.445
48
27
2.391
49
28
2.338
50
29
2.284
51
30
2.232
52
31
2.18
53
32
2.128
54
33
2.077
55
34
2.027
56
35
1.978
57
36
1.929
58
37
1.881
59
38
1.834
60
39
1.798
61
40
1.742
62
41
1.698
63
42
1.654
64
43
1.611
65
44
1.569
66
45
1.527
67
Voltage
(V)
1.487
1.447
1.409
1.371
1.334
1.298
1.263
1.228
1.195
1.162
1.13
1.099
1.069
1.04
1.011
0.983
0.956
0.929
0.904
0.879
0.854
0.831
SM PXD 1-E.3 GB