5.19
PXD30 OU8- 30 R410A
5.19.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
(1)
15
(1)
20
25
30
35
40
46
LEGEND
TC
Total Cooling Capacity, kW
SC
Sensible Capacity, kW
PI
Power Input, kW
WB –
Wet Bulb Temp., (
DB
Dry Bulb Temp., (
ID
Indoor
OU
Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).
SM PXD 1-E.3 GB
PERFORMANCE DATA & PRESSURE CURVES
ENTERING AIR WB/DB ID COIL ( °C)
DATA
15/21
TC
8.98
SC
5.68
2.12
PI
TC
8.69
5.57
SC
2.30
PI
TC
8.22
5.42
SC
2.49
PI
TC
7.69
5.25
SC
2.68
PI
7.12
TC
SC
5.00
2.89
PI
TC
6.47
SC
4.71
3.12
PI
TC
5.62
SC
4.34
3.41
PI
o
C)
o
C)
CONTENT
17/24
19/27
21/29
9.30
9.52
5.92
6.15
2.12
2.13
9.16
9.45
5.87
6.12
2.31
2.32
8.88
9.33
5.76
6.07
2.50
2.52
8.37
9.04
5.58
5.94
2.72
2.75
7.72
8.52
5.36
5.80
2.99
2.94
7.05
7.69
5.07
5.49
3.17
3.22
6.14
6.75
4.65
5.00
3.46
3.54
23/32
9.75
9.89
6.31
6.42
2.13
2.14
9.67
9.88
6.29
6.41
2.33
2.33
9.61
9.85
6.24
6.36
2.54
2.55
9.36
9.64
6.11
6.23
2.77
2.79
8.95
9.37
5.97
6.08
3.01
3.03
8.41
8.84
5.66
5.78
3.26
3.30
7.46
8.04
5.18
5.29
3.59
3.63
5-25