11.12.3
Condensation Pump (ECC/K model)
Mode: Cool, Dry, Auto
Temp: Selected desired temperature
Fan:
Any
Timer: Any
I FEEL:
Any
Control function:
Prevent Condensed water from Overflowing.
Overflow
Water Level
Normal
ON
OPER
OFF
LED
BLINK
ON
COMP
OFF
(WVL)
ON
PUMP
OFF
Notes:
1. The switch used for water level detection is closed under normal condition, and is open
when water overflow.
2. For the NEC version of MCU, the "Over Flow" & "Normal" condition are indicated by
logic "0" & "1" at the LEVEL4 input pin respectively.
3. For the Fujitsu version of MCU, the "Over Flow" & "Normal" condition are indicated by
logic "1" & "0" at the LEVEL4 input pin respectively.
4. The "Overflow" condition can activate the water pump in SB and operating modes.
SM PXD 1-E.3 GB
Overflow when
unit is ON
COMP/WVL is
forced OFF
8 min
CONTENT
CONTROL SYSTEM
Overflow when
unit is OFF
8 min
1 min
11-29