Electra COMPACT 7 Technical & Service Manual

Wall mounted, refrigerant r407c cooling only heat pump

Advertisement

Quick Links

Technical Service Manual
COMPACT 7,9,12
Wall Mounted
REFRIGERANT
R407C
COOLING ONLY
HEAT PUMP
Rev.:
Date:
01
11/01/2004

Advertisement

loading
Need help?

Need help?

Do you have a question about the COMPACT 7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Electra COMPACT 7

  • Page 1 Technical Service Manual COMPACT 7,9,12 Wall Mounted REFRIGERANT R407C COOLING ONLY HEAT PUMP Rev.: Date: 11/01/2004...
  • Page 2 O.D. suction mm(in) Φ9.53 Connection method indoor & outdoor Flared between the indoor height difference Max. 7m and outdoor unit tubing length Max. 10m 4m<Lin<8m:+5g/m Lin >8m: +9g/m additional charge ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 3 O.D. suction mm(in) Φ9.53 Connection method indoor & outdoor Flared between the indoor height difference Max. 7m and outdoor unit tubing length Max. 12m 4m<Lin<8m:+5g/m Lin >8m: +9g/m additional charge ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 4 O.D. suction mm(in) Φ12.7 Connection method indoor & outdoor Flared between the indoor height difference Max. 7m and outdoor unit tubing length Max. 12m 4m<Lin<8m:+5g/m Lin >8m: +9g/m additional charge ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 5 Upper limit 27°C DB 24°C DB, 18°C WB Heating Lower limit 20°C DB -9°C DB, -10°C WB 1 PH 198 – 242 V Voltage 3 PH 360 – 440 V ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 6 (FOR REAR ROUTING) TUBING WALL OPENING (FOR REAR LEFT ROUTING) AIR INTAKE AIR INTAKE AIR OUTLET WIRING CONNECTIONS LIQUID TUBE (FLARED) SUCTION TUBE (FLARED) VALVES CONNEDTIONS AIR INTAKE AIR OUTLET ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 7 (FOR REAR ROUTING) TUBING WALL OPENING (FOR REAR LEFT ROUTING) AIR INTAKE AIR INTAKE AIR OUTLET WIRING CONNECTIONS SUCTION TUBE (FLARED) LIOUID TUBE (FLARED) VALVES CONNEDTIONS 88.5 AIR INTAKE AIR OUTLET ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 8: Outdoor Unit

    ----CONNECTED ONLY HEAT-PUMB UNIT CAT NO 4526788/01 TO B OUTDOOR UNIT BU/BK DEICERTEMP SENSOR RT3 REVERSE COMP VALVE LEGEND Y/G--YELLOW/GREEN BN--BROWM BK--BLACK RD--RED BU--BLUE CAP--CAPACITOR OL--OVERLOAD BU/BK ----CONNECTED ONLY CAT.399221 HEAT-PUMB UNIT ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 9: Refrigeration Diagram

    REFRIGERATION DIAGRAM REFRIGERATION DIAGRAM MODEL: WMN 12_GCN R407C HEAT PUMP MODELS SERIES: IOD-7,9,12/CON-7,9,12 ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 10: Cooling Only

    ST MODELS COOLING ONLY IOD-7,9,12/CON-7,9,12 ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 11: Tubing Connections

    When the outdoor unit is installed above the indoor unit an oil trap is required every 5m along the suction line at the lowest point of the riser. In case the indoor unit is installed above the outdoor no trap is required. Outdoor Outdoor Indoor ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 12 ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 39 Model: IOD-7,9,12 IOD 7/9/12 ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 40 4525998 SENSOR BASE 4516263 Display assy 4526661 Control 4526660 Press cable board 4526662 Thermistor Indoor coil(BLACK) 438082 Thermistor room(BLACK) 4519813 The recommended quantity of spare part is 1-1.5 per cent. ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 41 Model: CON-12 ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 42 4-Way Valve Welding Assy. 4523869 Capi. Welding Assy. 4516156 Back Panel 4516637 Outdoor Unit Sensor 4519430 Condensor Assy. 4513965 Patition Plate 323156 Motor Support 261507 Fan Motor 293289 201130 Nut (For Fan) ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 43 Model: CON-7,9 RC R407C ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 44 4519609 Drain Jam 4526645 BOTTOM PLATE 4523609 MOTOR YDK20-6L 4523707 AXIAL FAN 4524076 4526681 protecting wire netting L. lifter 436358 The recommended quantity of spare part is 1-1.5 per cent. ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 45 4519609 Drain Jam 4526645 BOTTOM PLATE 4523609 MOTOR YDK20-6L 4523707 AXIAL FAN 4524076 4526881 protecting wire netting L. lifter 436358 The recommended quantity of spare part is 1-1.5 per cent. ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 46 Model: CON-7,9, ST R407C ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 47 MOTOR SUPPORT ASSY 4526645 BOTTOM PLATE 4523609 MOTOR YDK20-6L 4523707 AXIAL FAN 4524076 4526881 protecting wire netting L. lifter 436358 The recommended quantity of spare part is 1-1.5 per cent. ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 48 MOTOR SUPPORT ASSY 4526645 BOTTOM PLATE 4523609 MOTOR YDK20-6L 4523707 AXIAL FAN 4524076 4526881 protecting wire netting L. lifter 436358 The recommended quantity of spare part is 1-1.5 per cent. ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 49 Model: CON-12 ST R407C ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...
  • Page 50 (1/4") 4516522 Suction Tube 452785200 Discharge Tube 452786300 Capi. Assy 4516156 Back Panel 452763300 Condensor Assy. 4513965 Patition Plate 323156 Motor Support 261507 Fan Motor 293289 201130 Nut (For Fan) ELECTRA CONSUMER PRODUCTS LTD Rev.: A Series: IOD/CON Date: 12/01/2004...