Prepare Ground Wire
To properly ground the air conditioner unit, the ground wire must be secured to the frame of the
wall sleeve. When the air conditioner unit is placed inside of the wall sleeve, this ground wire will
be attached to the air conditioner frame to allow for proper grounding of the air conditioner unit.
Note: This step will require the use of a drill with a 1/8" drill bit. If your wall sleeve has been
previously installed, there may be no requirement to drill a new hole for the grounding screw.
1. Locate the following parts:
Grounding Screw (1)
Toothed Grounding Screw Washer
Ground Wire
2. Use your drill and
approximately 1" from the bottom and 3" from the front edge of the wall sleeve on the left side.
3. Attach one end of ground wire using 1 (one) Toothed Washer and 1 (one) Grounding Screw.
8
" bit to drill a hole for the grounding screw. The hole needs to be
1
/
8