System Components; Chassis Types; Adder Modules - Mircom FX-2000 Installation And Operation Manual

Hide thumbs Also See for FX-2000:
Table of Contents

Advertisement

System Components

Chassis Types

Mircom FX-2000
Fire Alarm Control Panel
Normal Condition
ENTER
December 31, 1999
SUPV.
TROUBLE
MONITOR
ALARM
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
SILENCE
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
ALARM
2nd STAGE
AUTO CANCEL
A.C. LINE
CIRCUIT
BREAKER
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#1
#5
#9
#13
#17
#21
#1
#5
#9
#13
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#2
#6
#10
#14
#18
#22
#2
#6
#10
#14
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
ZONE
BYPASS
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
#7
BYPASS
#15
#19
BYPASS
#23
BYPASS
BYPASS
#7
BYPASS
#15
#3
#11
#3
#11
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#4
#8
#12
#16
#20
#24
#4
#8
#12
#16
Mircom FX-2000
MENU
Fire Alarm Control Panel
Normal Condition
ENTER
CANCEL
December 31, 1999
INFO
ALARM
SUPV.
TROUBLE
MONITOR
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
FIRE
SILENCE
DRILL
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
SYSTEM
ALARM
RESET
2nd STAGE
LAMP
AUTO CANCEL
TEST
A.C. LINE
CIRCUIT
BREAKER
Mircom FX-2000
MENU
Fire Alarm Control Panel
Normal Condition
ENTER
CANCEL
December 31, 1999
INFO
ALARM
SUPV.
TROUBLE
MONITOR
QUEUE
QUEUE
QUEUE
QUEUE
SIGNAL
FIRE
SILENCE
DRILL
A.C. ON
PRE-ALARM
GND FAULT
GENERAL
SYSTEM
ALARM
RESET
ZONE
ZONE
ZONE
ZONE
ZONE
2nd STAGE
BYPASS
BYPASS
BYPASS
BYPASS
BYPASS
#17
LAMP
#1
#5
#9
#13
AUTO CANCEL
TEST
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
#2
BYPASS
BYPASS
BYPASS
#14
BYPASS
#6
#10
#18
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
BYPASS
#15
BYPASS
#3
#7
#11
#19
ZONE
ZONE
ZONE
ZONE
ZONE
BYPASS
BYPASS
BYPASS
#12
BYPASS
BYPASS
#4
#8
#16
#20

Adder Modules

Model
MENU
CANCEL
INFO
FIRE
DRILL
SYSTEM
RESET
FX-2003-6
LAMP
TEST
FX-2003-12
FX-2003S-12
FX-2017-12A
ZONE
ZONE
BYPASS
BYPASS
#17
#21
ZONE
ZONE
BYPASS
BYPASS
#18
#22
ZONE
ZONE
BYPASS
BYPASS
#19
#23
ZONE
ZONE
BYPASS
BYPASS
#20
#24
FX-2017S-12A
FX-2009-12
ZONE
BYPASS
#21
ZONE
BYPASS
#22
BYPASS
ZONE
#23
ZONE
BYPASS
#24
FX-2009S-12
EXC-0012
Model
DM-1008A, SGM-1004A,
RM-1008A
6 Amp Compact Main Chassis. Main Chassis with one analog loop, 4
Style Y or Z Indicating Circuits, and a 6 ampere Power Supply. This
compact main chassis comes complete with one Analog Loop Controller
(99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/
Y) Indicating Circuits (1.7 Amp each), a 4 line by 20 character back-lit
LCD display, 16 zone LED annunciator. The FX-2003-6 supports three
conventional adder modules and provides space for 3 adder modules.
This unit mounts in the BBX-1024.
Same as FX-2003-6. Mounts into a BBX-1024 Enclosure.
Same as FX-2003-12 except without an addressable loop.
12 Amp Mid-Size Main Chassis. Same as FX-2003-12, but with space
for mounting three adder modules on the main board plus additional
space in the chassis for an additional 14 adder boards. The FX-2017-12A
supports 16 conventional adder modules and has space for up to 17
adder modules 3 internal annunciator adder modules. This chassis
mounts in the BBX-1072A.
Same as FX-20017-12A except without an addressable loop.
12 Amp Large Main Chassis. Same as FX-2003-6, but with a 12
ampere power supply for mounting in the BB-5008 or the BB-5014
enclosure. The FX-2009-12 supports 16 conventional adder modules and
provides space for up to nine adder modules and two internal
annunciator adder modules.
Same as FX-2009-12 except without an addressable loop.
Expander Chassis to use with the FX-2009-12. It provides space for 12
adder modules and two internal annunciation modules. This chassis
mounts into the BB-5008 or BB-5014 backbox.
Loop and Circuit Adder Modules
FX-2000 Series Installation and Operation Manual
Description
Description
3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FX-2000 and is the answer not in the manual?

Table of Contents

Save PDF