ATTO Technology SC 5550E Installation And Operation Manual page 73

Faststream embedded storage controller
Table of Contents

Advertisement

MaxOpTemp
MaxOpTemp sets/displays the maximum operating temperature
in degrees Celsius. Valid entries are between 55 and 70
degrees.
set MaxOpTemp [55 - 70]
get MaxOpTemp
MediaScanErrorReport
Displays media scan error statistics for either a single block
device or all block devices in the system.
MediaScanErrorReport [BlockDevID | all]
Metrics
The Metrics CLI command offers control over the collection of
standard data metrics within a product via the command's
'Start', 'Stop', and 'Display' parameters.
Metrics [Start|Stop|Display|Clear] [[drive
[BlockDevID]]|all|running]
MinOpTemp
MinOpTemp sets/displays the minimum operating temperature
in degrees Celsius. Valid entries are between 0 and 15 degrees.
set MinOpTemp [0 - 15]
get MinOpTemp
OEMConfigFile
This command returns the "name" (i.e., the contents of the first
record) of the OEM configuration file stored in persistent
memory.
get OEMConfigFile
OpTempWarn
OpTempWarn sets/displays the offset in degrees Celsius when
a warning will be issued prior to a thermal control event. Valid
entries are between 0 and 15 degrees.
set OpTempWarn [0 - 15]
get OpTempWarn
Partition
Partition sets the specified partition to the specifed capacity in
gigabytes (GB), megabytes (MB), or blocks. The specified
capacity must be smaller than the specified partition's current
capacity. A new partition is created to acquire the remainder of
the original partition's space.
Partition [GroupName] [PartIdx] [capacity] [GB | MB |
blocks]
xviii
ATTO Technology Inc. FastStream SC Installation and Operation Manual
PartitionDisplay
PartitionDisplay outputs a list of all of the partitions available in
the specified RAID Group. The partitions are listed in order of
contiguousness (as opposed to index order). GroupName is the
ASCII name of the RAID Group for which partitions will be
displayed.
PartitionDisplay <GroupName>
PartitionMerge
PartitionMerge merges the specified contiguous partitions into
one partition. GroupName is the ASCII name of the RAID
Group containing the partitions to merge. PartIdx is the index of
a partition to merge, along with a number of contiguous
partitions to merge to that index. 'All' indicates that all partitions
in the RAID Group will be merged into a single Virtual Disk. The
RAID Group must not be in a NEW state. None of the partitions
to merge may be mapped.
PartitionMerge [GroupName] [[[PartIdx] [2-128]] | all]
PartitionSplit
PartitionSplit splits the specified partition into one or more
partitions whose capacities are evenly distributed among the
capacity of the original partition. GroupName is the ASCII name
of the RAID Group containing the partition to split. PartIdx is the
index of the partition to split. The partition to split cannot be
mapped. The RAID Group must not be in a NEW state.
PartitionSplit [GroupName] [PartIdx] [2-128]
PartitionWriteCache
Enable RAID internal Write Cache for higher write performance
with a small risk of data loss after a system failure. Disable
RAID internal Write Cache for a higher level of data integrity with
lower write performance.
set PartitionWriteCache [GroupName] [PartIdx] [enabled
| disabled]
get PartitionWriteCache [[GroupName] [PartIdx] | all]
PassThroughMode
PassThroughMode specifies the non-disk device types which
will be automatically mapped at boot time. The "all" option
allows all non-disk devices to be mapped. The "SES" option
allows dedicated SES processor LUNs to be mapped. The "non-
SES" option allows all non-SES devices to be mapped. The
"disabled" option disables the pass-through mode.
set PassThroughMode [all | SES | non-SES | disabled]
get PassThroughMode
PassThroughPersistent
PassThroughPersistent stores maps for currently-attached
passthrough devices to persistent memory.
PassThroughPersistent

Advertisement