Default values are appropriate for most configurations, but may be modified for your needs using ATTO
ExpressNAV Storage Manager.
It is best practice to change the default user name and
password to a user name and password important to
you. Other configurations may also be changed,

Changing current user name, password

It is best practice to change the user name and
password on all Telnet, FTP and ATTO ExpressNAV
Storage Manager sessions. Refer to the CLI
commands Username and Password in
1
Open a Command Line Interface session either
using Telnet or the serial port as shown in
Interface Options
on page 45.
2
Type set UserName [name].
3
Press Enter.
4
Type set Password.

Creating a read-only user name, password

You may wish to set up a read-only user name and
password to prevent changes to storage and
FastStream settings. Refer to the CLI commands
ReadOnlyPassword and ReadOnlyUsername in
Appendix
D.
1
Open a Command Line Interface session either
using Telnet or the serial port as shown in
Interface Options
on page 45, or use the
Advanced CLI page in an ExpressNAV Storage
Manager session as shown on page 40.

Changing system variables

You may change several system configurations to suit
your needs.
1
If you are not already in the ExpressNAV
Storage Manager, type the IP address of your
controller in a standard browser, click Enter
Here on the splash screen, then type in your
user name and password in the box provided.
Click OK.
2
Click on the Manage menu item on the left
hand side of the page.
26
ATTO Technology Inc. FastStream SC Installation and Operation Manual

5.0 Modify System Values

Appendix
D.
however, use extreme caution when changing default
values.
5
Press Enter.
6
Follow the instructions on the screen to confirm
your old and new password.
Note
The user name is case insensitive and
password is case sensitive.
The user name and password for all Telnet, FTP
and ATTO ExpressNAV Storage Manager
sessions is changed.
2
Type set ReadOnlyUsername [name].
3
Press Enter.
4
Type set ReadOnlyPassword.
5
Press Enter.
6
Follow the instructions on the screen to confirm
the read-only password.
The read-only user name and read-only password for
all user interface sessions is changed.
3
Click on the FastStream SC arrow.
4
Click on the System Configuration radio
button.
5
Click on Next.