CAPowerStatus
(CacheAssure Models only)
Returns the current status of the CacheAssure Power Module.
This includes whether or not it is installed and whether or not it
is fully charged.
get CAPowerStatus
ClearEventLog
Clears the contents of the event log.
ClearEventLog
Date
Date sets/displays the current date. The date range is
01/01/2000 to 12/31/2099.
set Date [MM/DD/YYYY]
get Date
DeleteAllMaps
Removes all mapped devices from the map table. Upon the
subsequent POST, if no maps are present the default maps will
be loaded.
DeleteAllMaps
DeleteScheduledTasks
Deletes a scheduled task with the Id returned by
DisplayScheduledTasks.
DeleteScheduledTasks [Id]
DisplayEventLog
DisplayEventLog can be used to enable the "DisplayEventLog"
mode which facilitates scrolling through the event log. The
parameters within the DisplayEventLog are [ + | - | = | q ] The
optional parameter is the number of lines to be displayed as a
single page with no user interaction.
DisplayEventLog <n>
DisplayEventLogFilter
DisplayEventLogFilter is used to filter the display of data for
specified subsystems and levels during "DisplayEventLog"
mode.
Default: all all all
sett DisplayEventLogFilter [subsys | all] [level | all] [all |
none]
get DisplayEventLogFilter [subsys | all] [level | all]
DisplayScheduledTasks
Immediate command that displays all outstanding scheduled
tasks.
DisplayScheduledTasks
xiv
ATTO Technology Inc. FastStream SC Installation and Operation Manual
DriveAssureReport
Displays drive timeout error statistics for all member drives in
the specified RAID Group.
DriveAssureReport [GroupName]
DriveHealth
(all but SC 8250)
Changes the system's ability to acquire drive health data from
connected drives. Issuing this command during I/O operations
may adversely affect performance.
set DriveHealth [enabled | disabled]
DriveHealthDisplay
(all but SC 8250)
Retrieves and displays S.M.A.R.T. data from SATA disk drives,
and MEDIUM DEFECT and INFORMATION EXCEPTIONS
counts from other drives. Issuing this command during I/O
operations may adversely affect performance.
DriveHealthDisplay [BlockDevID | all]
DriveHealthStatus
(all but SC 8250)
Displays the current S.M.A.R.T. support of specified SATA disk
drives and MEDIUM DEFECT and INFORMATION
EXCEPTION support in other disk drives.
DriveHealthStatus [BlockDevID | all]
DriveTest
Immediate command which starts or stops a drive test with the
previously specified configuration and drive list. Drives which
are in-use by the test are not available for RAID configuration or
RAID operations. Only one test can be run at a time.
DriveTest [Begin | Cancel]
DriveTestClearList
Specifies drives to be removed from the drive test list. The 'drive
BlockDevID' parameter will remove the specified drive from the
list. The 'all' parameter automatically removes all drives from the
list.
DriveTestClearList [drive [BlockDevID] | all]
DriveTestConfig
Configures the drive test to perform one of the following
operations: initialize (destructive write-only), mediascan
(destructive for sectors with medium errors), read (non-
destructive read-only), verify (destructive verify), or init-verify
(destructive write-read-verify). The test is not started until the
DriveTest Begin command is given. A new configuration may
not be set while a drive test is being performed.
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig