Time
start -
one-off
Time
start -
daily
Time
start -
interval
Cyclic
start
Contact
start
Radiation
sum
start
When automated irrigation starts are executed, the irrigation program will
always use the recipe settings of the valve group in the period that is
currently active. If no period is currently active, irrigation will not start
automatically.
24
HortiMaX-Go!
Start irrigation once on the pre-set date and time (with the
recipe settings applicable at that time)
Start irrigation on the selected days at a pre-set time (with
the recipe settings applicable at that time)
Start irrigation at the pre-set time with an interval of a pre-
defined number of days.
A cyclic start applies for a particular period and valve group.
After the pre-set cycle time, the valve group will be re-
activated (i.e. irrigation will start again). The cycle time will
be reset after each start (of each type).
The group will be activated when the selected contact is
activated.
The group will be activated once the pre-set radiation sum
(J/cm2) is reached. The radiation sum will be reset once the
irrigation cycle has been completed and at midnight (0.00
hours).