Three columns will appear:
The icon
is the limit value for the humidification stage; this means it is too dry in
your greenhouse.
The icons
are the limit values for the dehumidification stage; this means it is too
humid in your greenhouse.
In the above example, the air vents on the leeward side will be limited to a maximum
position of 20% if the relative humidity (RH) drops below 60%. If the RH rises above
80% or 90%, the minimum vent position will be 2% and 5% respectively. If the RH
rises above 90%, the vent position on the windward side will be at least 3%.
The humidity settings for the vents and screens act as limitations, i.e.
minimum or maximum positions. Although a higher or lower value may be
desirable based on the ambient temperature, the vent or screen position may
be limited because of the current humidity level. The gale, rain and wind
overrides have priority over the humidity settings.
Control example:
When it is too dry or too hot in your greenhouse, you can switch on the humidification
system if you have one. In the example below, the humidification system will switch
on if the ambient temperature rises above 25°C or the RH (relative humidity) drops
below 60%. If the RH rises too high (above 90%), the humidification system will
switch off: