HortiMaX Go! User Manual page 12

Table of Contents

Advertisement

Depending on your greenhouse equipment and design, there are various ways of
cooling or heating your greenhouse. The ambient temperature can be lowered by
opening the roof or side vents, switching the heating system off, switching the cooling
system on, or a combination of these actions. The control actions that are applied
during each stage will depend on your settings on the stage screen. These settings
can be programmed for the entire day or for up to four daily periods.
The stage screen can be opened from the individual control screens.
No. Description
1
Breadcrumb trail: shows for which zone (zone 1
stage screen has been opened
2
Icons for fixed position
3
Stage limit value
4
Control with specific settings
5
Period for which stage control applies
6
Buttons to display or hide the manual control and humidification columns
The top bar of the stage screen shows the different stages. In the screenshot above,
there are two cooling stages and two heating stages. You can set multiple heating
stages (up to 2) and cooling stages (up to 6). This allows you to control the ambient
temperature even more accurately.
The stage screen resembles a table. The top bar shows the stages with the
corresponding values. In the screenshot below, the desired ambient temperature is
between 18.0°C and 20.0°C
When the temperature drops below 18.0°C, the first heating stage will start. When the
temperature rises above 20.0°C, the first cooling stage will start. When the
temperature rises above 22.0°C, then the second cooling stage will start.
12
HortiMaX-Go!
and the various stages
.
in the above screen) the

Advertisement

Table of Contents
loading

Table of Contents