Quality Assurance Testing - Sierra Wireless MC5725 Hardware Integration Manual

Cdma and gsm / umts mini card
Hide thumbs Also See for MC5725:
Table of Contents

Advertisement

CDMA and GSM / UMTS Mini Card Hardware Integration Guide
Note: Actual measured results
will vary, depending on your
testing setup.
Note: QA is an ongoing process
based on random samples from
a finished batch of devices.
96
In the event of a discrepancy in values between this guide and the Product Specification Document (PSD), the PSD takes precedence.
AT!AVCODECSTG=0,FFFF
c.
audio profile 0)
3.
Take measurements using the following commands (Note 
that the module has a gain of 4 dB in audio loopback 
mode.)
Press the ACV button to measure the AC level.
a.
·
Expected range: 1–2.5 VAC
b.
Press the FREQ button to measure the frequency.
·
Expected value: 1 kHz
Press the Shift and THD buttons at the same time to 
c.
measure the total harmonic distortion.
·
Expected value: < 1%
d.
Reset the audio parameters:
·
(MC5725V / 
AT!AVAUDIOLPBK=0
mode)
·
(MC8775V / MC8785V / MC8790V / MC8791V / 
MC8792V)
AT!AVDEF
parameters to default values)

Quality assurance testing

The quality assurance tests that you perform on your finished 
products should be designed to verify the performance and 
quality of your devices.
The following are some testing suggestions that can confirm 
that the antenna is interfaced properly, and the RF module is 
calibrated and performs to specifications:
Module registration on cellular networks
Power consumption
Originate and terminate data and voice (if applicable) calls
Cell hand‐off
Transmitter and receiver tests
FER (Frame Error Rate) as an indicator of receiver sensi‐
tivity / performance
Channel and average power measurements to verify that 
the device is transmitting within product specifications
RF sensitivity tests
‐specific:
MC57xx
Waveform quality tests (calculating the "rho" parameter) 
·
to compare the CDMA signal's power distribution 
against the ideal distribution—rho must be >0.97 with 
max freq error of 0.5 to pass.
FER testing—test the receiver sensitivity for conditions 
·
of minimum cell power. FER can be measured for the 
Proprietary and Confidential
(Sets sidetone gain for 
MC5727V  /  MC5728V )
(Disables audio loop‐back 
(Sets configurable audio 
2130114

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents