Emerson Rosemount 8742C Reference Manual page 30

Magnetic flowmeter transmitter with foundation fieldbus and magnetic flowmeter flowtube
Table of Contents

Advertisement

Rosemount 8742C
See "Safety Messages" on pages 3-1 and 3-2 for complete warning information.
3-8
NOTE
Do not bolt one side at a time. Tighten each side simultaneously. Example:
1. Snug left
2. Snug right
3. Tighten left
4. Tighten right
Do not snug and tighten left and then snug and tighten right. Failure to do so
will result in liner damage.
Always check for leaks at the flanges after tightening the flange bolts. Failure
to use the correct flange bolt tightening methods can result in severe damage.
All flowtubes require a second torquing twenty-four hours after initial flange
bolt tightening.
Table 3-1. Flange Bolt Torque Specifications for
Rosemount 8705 and 8707 High-Signal Flowtubes
Size Code
Line Size
1
2
005
/
-inch (15 mm)
010
1 inch (25 mm)
1
2
015
1
/
inch (40 mm)
020
2 inch (50 mm)
030
3 inch (80 mm)
040
4 inch (100 mm)
060
6 inch (150mm)
080
8 inch (200 mm)
100
10 inch (250 mm)
120
12 inch (300 mm)
140
14 inch (350 mm)
160
16 inch (400 mm)
180
18 inch (450 mm)
200
20 inch (500 mm)
240
24 inch (600 mm)
300
30 inch (750 mm)
360
36 inch (900 mm)
00809-0100-4793, Rev CA
Teflon/Tefzel liner
Class 150
Class 300
(pound-feet)
(pound-feet)
8
8
8
12
13
25
19
17
34
35
26
50
45
50
60
82
55
80
65
125
85
110
85
160
120
170
110
175
165
280
195
415
280
575
Reference Manual
August 2004
Polyurethane liner
Class 150
Class 300
(pound-feet)
(pound-feet)
7
18
14
11
23
23
17
32
30
37
42
55
40
70
55
105
70
95
65
140
95
150
90
150
140
250
165
375
245
525

Hide quick links: