Tektronix RSA5100A Series Programming Manual page 1034

Hide thumbs Also See for RSA5100A Series:
Table of Contents

Advertisement

Command Descriptions
Arguments
Examples
[SENSe]:PHVTime:FREQuency:CENTer
Conditions
Group
Syntax
Related Commands
Arguments
Examples
[SENSe]:PHVTime:FREQuency:SPAN
Conditions
Group
Syntax
2-1016
None
SENSE:PHVTIME:CLEAR:RESULTS
Sets or queries the center frequency in the Phase versus Time measurement.
NOTE.
The center, start and stop frequencies are set interlocking each other with
the following relationships: (start frequency) = (center frequency) - (span)/2 and
(stop frequency) = (center frequency) + (span)/2.
Measurement views: Phase versus Time
Sense commands
[SENSe]:PHVTime:FREQuency:CENTer <value>
[SENSe]:PHVTime:FREQuency:CENTer?
[SENSe]:PHVTime:FREQuency:STARt,
specifies the center frequency.
<value> ::
<NRf>
Range: 0 Hz to 6.2 GHz (RSA6106A) / 14 GHz (RSA6114A).
SENSE:PHVTIME:FREQUENCY:CENTER 7.5GHz
7.5 GHz.
Sets or queries the frequency span in the Phase versus Time measurement.
Measurement views: Phase versus Time
Sense commands
[SENSe]:PHVTime:FREQuency:SPAN <value>
[SENSe]:PHVTime:FREQuency:SPAN?
RSA6100A Series & RSA5100A Series Programmer Manual
restarts multi-trace functions.
[SENSe]:PHVTime:FREQuency:STOP
sets the center frequency to

Advertisement