9.3

Test and indication flow

Expander 1
Zones 9-16
Relay #1 allocated seismic test
Seismic Inputs
Zone 9 = ISN-SM-50
Zone 10 = ISN-SM-90
Zones 9 & 10 tested via GMXS1
Seismic Outputs
Output simultaneously activates
all GMXS1 test transmitters
9.4

User Interface

When using the compact keypad as the user interface the following menu options will be available
for automatic and manual testing of all of the detectors on a system.
To perform a seismic test, enter the required passcode and follow the steps indicated below;
a) Scroll to TEST > SEISMIC TEST.
b) Press SELECT.
c) Select TEST ALL AREAS, or select an individual area to test.
d) If you select an individual area to test, you can select either TEST ALL ZONES or select a
 The message 'SEISMIC TEST' is displayed on the keypad and flashes while the test is being
performed,
 If the test fails, the message 'SEISMIC FAIL' is displayed. If the "i" or VIEW key is pressed, a
scrollable list of the failed zones is displayed.
 If the test succeeds, 'SEISMIC OK' is displayed.
Bosch Security Systems
Seismic test command
Automatic
Manual command from keypad
SPC Panel
Zones 1-8
Output 3 allocated Seismic
Seismic Inputs
Zones 1, 3, 4 & 8 = ISN-SM-90
Zones 1 & 8 tested via GMXS1
Zones 3 & 4 tested via GMXS5
Seismic Outputs
Output simultaneously activates
all GMXS1 and GMXS5 test trans-
specific seismic zone to test.
Seismic Detectors Application Guide
Auto/set
test
Relay #1 allocated seismic test
mitters
Interface to SPC Panel/System
Expander 2
Zones 17- 24
Seismic Inputs
Zones 21, 23 & 24 = ISN-SM-90
Zones 21 & 24 tested via GMXS1
Zones 23 & 4 tested via GMXS5
Seismic Outputs
Output simultaneously activates all
GMXS1 and GMXS5 test transmit-
ters
9
57
I-200153-1
04.2016