®
Intel
Server Chassis H2000 Family TPS
Power Sub-System
cooling or excessive ambient temperature. In an OTP condition the PSU will shut down. When
the power supply temperature drops to within specified limits, the power supply shall restore
power automatically, while the 12VSB remains always on. The OTP circuit must have built in
margin such that the power supply will not oscillate on and off due to temperature recovering
condition. The OTP trip level shall have a minimum of 4°C of ambient temperature margin.
3.7
PMBus*
The PMBus* features are requirements for power supply unit for use in server systems. This
specification is based on the PMBus* specifications part I and II, revision 1.1. The power supply
device address locations are shown below:
Figure 13. Power Supply Device Address
The PMBus* from PDB is connected to BMC of all four nodes. Only one board BMC is assigned
to be the master BMC and communicate with PSU as single point. Other board BMCs receive
PSU data from the master BMC. In case the master BMC is down, one of the slave board BMC
will be promoted automatically as master BMC and maintain the communication.
3.7.1
PSU Address Lines A0
Address pins A0 is used by end use system to allocate unit address to a power supply in
particular slot position.
Revision 1.5
31
Intel order number: G59059-006