8-1 General Specifications
Operation method
AC Sensing
LCD
Sampling rate
Range selection
Over-range indication
Polarity indication automatic selection
Low battery indication
Environmental condition
Operating temperature /
humidity
Storage temperature / humidity
Power supply
Power consumption
Battery life
Safety standards
EMC
Clamp sensor (CT) clamp size
Dimensions
Weight
Auto power off
Accessories
– method
True RMS AC coupling
6000 counts
5 times/sec nominal
Auto and Manual
"OL" shown in numerical part.
"–" indicated only when negative input.
"
" lights or flickers at about 2.4 V or below.
Altitude 2000 m or below, pollution degree II.
5°C to 40°C and maximum relative humidity 80%
for temperature up to 31°C decreasing linearly to
50% relative humidity at 40°C (No condensation)
-20°C
60°C, 70%R.H or below (with battery removed).
R03 1.5V x 2 pieces
2.8mA at DCV (typical)
Approx. 90 hours at DCV (Disable Auto power off)
IEC61010-2-032 (2002), CAT.III 600V
IEC61010-031
IEC61326
In an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
Max. 42 mm
238(L) X 95(W) X 45(H) mm
Approx. 290g (battery included)
About 3~7 min. after power on.
Battery (built-in), Test leads (TL-23), Carrying
case (C-DCL1000), Instruction manual
— 21 —