Specifications; General Specifications - Sanwa SE9100 Instruction Manual

Digital elevator speedometer
Table of Contents

Advertisement

[8] SPECIFICATIONS

8-1 General Specifications
Item
Measurement
ranges
Measuring time
Auto power OFF When power has been left on for about 3
Measurement
hold
Averaging
Memory
Displays
Display updating
interval
Analog output
Battery alarm
Power supply
Current drain
Battery life
Operating
temperature/
humidity ranges
Storage temperature/
humidity ranges
(Batteries removed)
Dimensions
Mass
Linear velocity: 0.1 - 2000.0 (m/min)
Rotation speed: 1 – 20000 (r/min)
Distance: 0 – 999 (mm)
10 ms
minutes after the last operation.
Optionally extendable to 1 hour.
CH1/CH2/Max. value * All independently.
CH1/CH2: Hold possible by Main Unit panel +
External triggering.
Desired setting between 1 – 10 times
Max. 10 sets can be saved in internal memory.
5-digit red 7-segment LED x 2 rows
200 ms
Voltage range: 0 – 2 V (Full-scale value can be
selected.)
Output accuracy: ±(0.8 % + 2 mV )
Indication LED lights when voltage drops below
about 4.5 V during operation.
Operation stops at about 3.8 V.
Instrument cannot be started up at about 4.0 V
or less.
LR6 ("AA"-size alkaline battery) x 4
Max. about 100 mA
20 hours or more
5 ºC to 40 ºC,
Max. 80 %RH (without condensation)
-10ºC to 40 ºC: ≤80 %RH (without condensation)
40 ºC to 50 ºC: ≤70 %RH (without condensation)
174 (H) x 50 (W) x 50 (D) mm (without projections)
Main Unit Approx. 510 g (incl. batteries)
- ... 35 ... -
Specifications

Advertisement

Table of Contents
loading