System Management Operations - Canon LBP6670dn Series Service Manual

Table of Contents

Advertisement

5
Trouble Shooting > Updater > Overview > System Management Operations

■ System Management Operations

● Various Setting
Setting Log Level
This section describes how to set system log levels.
1. Activate [Register/Updater Software (Management Settings)] from browser.
1). Enter [https://machine's IP address:8443/svm/] to the URL of browser.
2). Type the password [*28*] then log in it.
3). After login, select [System Settings] > [Edit].
2. Select a log level from [Log Level] dropdown list.
• [Log Level]:
Select one of 5 levels ranging from [0] to [4]. (The default [3].)
See the table below for logs output in each level.
5
Trouble Shooting > Updater > Overview > System Management Operations
Log Level
Trace
0
1
2
3
4
NOTE:
This list shows the contents of the Log Output.
Log Output
Trace
Information
Important Message
Ordinary Error
System Error
F-5-36
3. Press [Configure] button to set the selected log level. Now the log level is successfully set.
Caution:
When you set it to log level 4, a performance falls, and the log acquisition takes time
F-5-37
remarkably .
Log Output
Information
Important Message
-
-
-
-
-
-
-
-
Yes
-
Yes
Yes
Yes
Yes
Yes
Description
Detailed logs for debug
Logs related to operations done on the system
Update logs output by firmware type
Installation logs by MEAP application
Logs related to enabled functions by system option
Logs for ordinary errors
Logs for internal system errors
5-27
Ordinary Error
System Error
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
T-5-19
5-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lbp6680x series

Table of Contents