INSTALLATION
2
Figure 2-22: Procedure: How to attach an antenna extension
WARNING!
Make sure that you do not damage the PTFE cone when you remove or install the antenna.
Procedure 1: How to attach an antenna extension
1 Remove the 3 hex head screws from the antenna with the 10 mm wrench.
2 Remove the antenna. Make sure that you do not damage the PTFE cone when you remove the
antenna.
3 Attach the antenna extension below the flange. Make sure that the antenna extension is fully
engaged. Make sure that you do not damage the PTFE cone when you attach the antenna ex-
tension.
4 Attach 3 hex head screws to the antenna extension with a 10 mm wrench. Tighten the screws
to a torque of 8 Nm.
5 Attach the antenna below the antenna extension.
6 Attach 3 hex head screws to the antenna with a 10 mm wrench. Tighten the screws to a torque
of 8 Nm.
i
If the antenna extension is supplied with the device, it is not necessary to change the device
settings. End of the procedure.
7 If the antenna extension is supplied after delivery of the device, it is necessary to change the
device settings. Make a selection from one of the procedures (2A or 2B) that follow: straight
18