Troubleshooting
PROBLEM
Increased gas discharge
temperature.
Seal head will not install
properly.
Leakage across seal body.
Page 80
POSSIBLE CAUSE
Air in refrigeration system.
Twisted when installed.
Installed wrong size, distorted
O-ring, or cut O-ring.
Wrong O-ring compound (ring
is a different color than
normal).
Damaged seal head insert.
Recess in head for seal head
insert damaged.
O-ring twisted when installed.
Wrong O-ring compound (ring
is a different color than
normal).
Damaged seal body.
Damaged seal backing ring.
Damaged shaft at O-ring
sealing surface.
Seal ring rotating in seal
body.
95-03057
Waukesha Cherry-Burrell
SUGGESTED ACTION
Refer to "Water and Air in
Refrigeration System" on page 82.
Lubricate before installing.
Replace O-ring.
Replace with specified O-ring. If
unsure of correct O-ring, contact
WCB.
Replace entire seal.
Contact WCB for repair instructions.
Lubricate before installing.
Replace with specified O-ring. If
unsure of correct O-ring contact WCB.
Replace entire seal.
Replace seal backing ring.
Contact WCB for repair instructions.
Assemble ring in body without
lubrication.