Hot Gas Pressure Regulating Valve; Pressure Relief Valve; Suggested Media Piping For Liquid Over Feed Refrigeration - SPX Votator II Instruction Manual

Scraped surface heat exchanger
Table of Contents

Advertisement

Installation
DANGER: Never install a shutoff
valve in a relief line.
Suggested Media Piping
for Liquid Over Feed
Refrigeration
1
2
Figure 10- Suggested Media Piping, Liquid Over Feed or Pumped Refrigeration
Page 16

Hot Gas Pressure Regulating Valve

Systems with hot gas include a solenoid-operated Pressure
Regulating Valve for introducing and maintaining constant
downstream pressure for hot gas inlet.
Pumped Refrigeration Systems include a solenoid operated Hot
Gas Purge Valve for each Votator hot gas discharge line.

Pressure Relief Valve

This valve is located on the accumulator and should be
exhausted to outside the building. The valve is factory set to
relieve at the design pressure of the accumulator.
The liquid feed solenoid valve, when opened, allows liquid
refrigerant to flow into the jacket of the heat exchanger. The flow
is regulated by a manually set flow control valve. Cooling is
achieved when the pressure control valve is opened, causing the
pressure in the jacket to be reduced. This causes the liquid
refrigerant to change phase, absorbing heat from the heat
exchanger tube and product. The cooling rate is controlled by the
back pressure on the system and stops when the valve is closed.
Hot gas is used to push all of the remaining liquid from the
system into the ammonia low pressure receiver and quickly warm
the system. The low pressure receiver in the compressor room is
designed to separate the liquid from the vapor before re-
compressing.
4
3
1
95-03057
Waukesha Cherry-Burrell
16
S
5
17
8
S
9
10
S
12
S
13
14
13
6
or
7
PI
11
18
S
15
HE100-053a
11/2012

Hide quick links: