Suggested Media Piping For Water Or Liquid - SPX Votator II Instruction Manual

Scraped surface heat exchanger
Table of Contents

Advertisement

Waukesha Cherry-Burrell
Table 1: Call Outs For Figure 8
1. Steam IN
2. Strainer
3. By-Pass Line
4. Steam Pressure Regulator
5. Steam Solenoid
6. Temperature Regulator
7. I/P
8. Temperature Control
9. Product OUT
10. Product IN
11. Drain Valve
12. Condensate Trap
Suggested Media Piping
for Water or Liquid
Table 2: Call Outs For Figure 9
1. Media IN
2. Product OUT
3. Product IN
4. Temperature Regulator
5. Media OUT
6. I/P
7. Temperature Control
11/2012
3
PI
1
4
2
10
11
Figure 8- Suggested Media Piping, Steam
The media piping should flow counter-current to the product flow,
and should be circulating at a rate of 50 gpm. The suggested
arrangement automates the source flow to the actual heat
exchange requirements to provide maximum control of the
process.
TI
1
PI
3
TI
4
TY
6
5
Figure 9 - Suggested Media Piping, Water or Liquid
95-03057
Installation
PI
5
6
TY
7
PI
12
MS
TI
PI
TC
7
TC
8
TE
9
HE100-056
2
TE
TI
HE100-057
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents