Suggested Media Piping For Gravity Refrigeration - SPX Votator II Instruction Manual

Scraped surface heat exchanger
Table of Contents

Advertisement

Waukesha Cherry-Burrell
1. Safety Relief Valve
2. Product IN
3. Product OUT
4. Low Pressure Solenoid Valve, see Item 10
5. Hot Gas
6/7. Electric Control Signal or Instrument Air
Regulated to 60 PSI
8. Low Pressure Regulating Valve, see Item 10
9. High Pressure Regulating Valve, see Item 10
Suggested Media Piping
for Gravity Refrigeration
1
11
13
PI
10
11
Level Switch Control
Figure 11 - Suggested Media Piping, Gravity Refrigeration - HORIZONTAL
11/2012
Table 3: Call Outs For Figure 10 (on page 16)
10. Dual Pressure Regulating Valve (includes Items 4, 8 and 9)
11. To Refrigerant Low Pressure Receiver
12. Hot Gas Purge Valve
13. Flow Control Valve
14. Liquid Feed Solenoid Valve
15. Liquid Refrigerant from Low Pressure Receiver
16. Hot Gas Reducing Valve
17. Hot Gas Solenoid Valve
18. Hot Gas Pressure Regulating Valve
Liquid refrigerant from the receiver is stored in a surge drum
located above the Votator II. The level in the surge drum is
automatically controlled by the level system provided with the
equipment. Gravity forces the refrigerant into the cooling jacket
where it comes into contact with the heat transfer tube. The warm
product causes a portion of the liquid refrigerant to change
phase, causing the heat transfer tube and the product to be
cooled. The cooling rate is controlled by the refrigerant back
pressure, and hot gas can be used to push the liquid refrigerant
from the Votator cylinder and rapidly warm the system.
NOTE: Set high pressure regulating valve 5 to 10 psi higher than
outlet pressure of hot gas pressure reducing valve and lower than
the relief setting.
2
1
PI
12
7
OR
Level Master Control
19
9
18
95-03057
5
PI
20
S
3
4
14
22
S
21
S
12
10
11
13
Installation
6
15
S
17
16
HE100-061a
Page 17